User guide
328 ExtremeWare 7.2e Installation and User Guide
Troubleshooting
System Odometer
Each field replaceable component contains a system odometer counter in EEPROM. You can use the
show switch command to see how long an individual component has been in service since it was
manufactured.
Reboot Loop Protection
If the system reboots due to a failure that remains after the reboot, it reboots when it detects the failure
again. To protect against continuous reboot loops, you can configure reboot loop protection using the
following command:
configure reboot-loop-protection threshold <time-interval> <count>
If the switch reboots the specified number of times within the specified time interval, it stops rebooting
and comes up in minimal mode. If you reboot the switch manually or
run diagnostics commands,
the time interval and count are both reset to 0.
Minimal Mode
In minimal mode, only the CPU, NVRAM, management port, and minimal tasks are active. The
following commands are supported in minimal mode:
• reboot
• unconfigure switch all
• unconfigure switch
• use image
• use configuration
• download bootrom
• download image
• download configuration
• configure iparp
• configure vlan ipaddress
• configure iproute add default
• configure diagnostics
• show iproute
• show iparp
• show vlan
• show version
• show log
• ping
• clear log
• clear log diag-status