User guide
Commands for Configuring and Monitoring EAPS
Summit24e3 Switch Installation and User Guide 129
Preforwarding Timer interval: 3 sec
Last update: From Master Id 00:E0:2B:81:20:00, Sat Mar 17 17:03:37 2001
Eaps Domain has following Controller Vlan:
Vlan Name VID
"rhsc" 0020
EAPS Domain has following Protected Vlan(s):
Vlan Name VID
"traffic" 1001
Number of Protected Vlans: 1
The following example of the show eaps {<name>} detail command displays detailed EAPS
information for a single EAPS domain named “eaps2” on the master node. Table 30 describes significant
fields and values in the display.
* Baker15:4 # show eaps2 detail
Name: "eaps2" (instance=0)
State: Complete [Running: Yes]
Enabled: Yes Mode: Master
Primary port: 14 Port status: Up Tag status: Tagged
Secondary port: 13 Port status: Blocked Tag status: Tagged
Hello Timer interval: 1 sec Fail Timer interval: 3 sec
Eaps Domain has following Controller Vlan:
Vlan Name VID
"rhsc" 0020
EAPS Domain has following Protected Vlan(s):
Vlan Name VID
"blue" 1003
"traffic" 1001
Number of Protected Vlans: 2
Table 30: show eaps Display Fields
Field Description
EAPS Enabled: Current state of EAPS on this switch:
• Yes—EAPS is enabled on the switch.
• no—EAPS is not enabled.
Number of EAPS instances: Number of EAPS domains created. There can only be
one EAPS domain on this platform.
EAPSD-Bridge links: The total number of EAPS bridge links in the system.
The maximum count is 255. Each time a VLAN is
added to EAPS, this count increments by 1.
Name: The configured name for this EAPS domain.
(Instance= ) The instance number is created internally by the
system.