Installation guide

EPS-600LS External Power Module
Summit Family Switches Hardware Installation Guide
49
The PoE capability of the Summit X450e-48p or X250e-48p varies depending on the number of external
power modules in use. Table 11 summarizes the PoE power behavior for the Summit X450e-48p or
X250e-48p switch based on the number of power modules in use.
Single 600-LS Module Configuration: Redundant PoE Power
A single EPS-600LS power module provides redundant PoE power capability with the same 370-watt
capacity as the internal power supply. The internal Summit X450e-48p or X250e-48p power supply is
capable of 370 W of PoE power: 15.4 W supplied to each port for a 24-port configuration and 7.7 W
supplied to each port for a 48-port configuration.
If the internal power supply fails, the external power module will provide power to PoE devices at
the same power levels as the internal power supply without any power interruptions.
If the EPS-600LS power module fails or is removed, the internal power supply continues to provide
PoE power without any power interruptions.
Dual 600-LS Module Configuration: Full Power
Two EPS-600LS power modules provide full power at 740 W, which allows 15.4 W of PoE power to all
48 ports. In this full-power configuration, the internal power supply is disabled, and therefore
redundant power is not available.
Triple 600-LS Module Configuration: Full Redundant Power
Three EPS-600LS power modules provide the full 740 W of power for 15.4 W of PoE power to all 48
ports. In addition, this configuration provides 2:1 redundancy. Should one of the EPS-600LS power
modules fail, the third power module continues to provide uninterrupted full PoE power. The internal
power supply is disabled in this configuration.
Internal-to-External PSU Transfer
This section describes the conditions that would cause the Summit X450e-48p or X250e-48p switch to
draw power from the external power unit.
Internal PSU Failure with Single EPS-600LS Module. When an EPS-C with a single EPS-600LS is connected
to the Summit X450e-48p or X250e-48p switch and the internal PSU fails, power is drawn from the EPS-
600LS without power interruption to the PoE connected devices.
Table 11: External Power Modules and Corresponding PoE Behavior
Internal PSU
Status
EPS-600LS (1x) EPS-600LS (2x) EPS-600LS (3x)
External PSU/Chassis
Failed/Disconnected
Internal PSU:
Power On
370 W of
redundant power
740 W of
external power only
Internal PSU disabled
740 W of
external power only
with 2 + 1 redundancy
Internal PSU disabled
370 W of
internal power only
Internal PSU:
Power Failure
370 W of
external power only
740 W of
external power only
740 W of
external power only
with 2 + 1 redundancy
No PoE power