TECHNICAL SPECIFICATION ExtremeRouting SLX 9850 Technical Specifications 9035334-03 15 June 2018
© 2018, Extreme Networks, Inc. All Rights Reserved. Extreme Networks and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks, Inc. in the United States and/or other countries. All other names are the property of their respective owners. For additional information on Extreme Networks Trademarks please see www.extremenetworks.com/company/legal/trademarks. Specifications and product availability are subject to change without notice.
Contents Preface...................................................................................................................................................................................................................................5 Document conventions............................................................................................................................................................................................................................
ExtremeRouting SLX 9850 Technical Specifications 9035334-03
Preface • • • • Document conventions...................................................................................................................................................................................... 5 Extreme resources................................................................................................................................................................................................6 Document feedback..............................................................
Extreme resources Format Description Identifies command syntax examples. Command syntax conventions Bold and italic text identify command syntax components. Delimiters and operators define groupings of parameters and their logical relationships. Convention Description bold text Identifies command names, keywords, and command options. italic text Identifies a variable. [] Syntax components displayed within square brackets are optional.
Contacting Extreme Technical Support Contacting Extreme Technical Support As an Extreme customer, you can contact Extreme Technical Support using one of the following methods: 24x7 online or by telephone. OEM customers should contact their OEM/solution provider. If you require assistance, contact Extreme Networks using one of the following methods: • GTAC (Global Technical Assistance Center) for immediate support – – Phone: 1-800-998-2408 (toll-free in U.S. and Canada) or +1 408-579-2826.
ExtremeRouting SLX 9850 Technical Specifications 9035334-03
ExtremeRouting SLX 9850 Technical Specifications System specifications System component Description Enclosure SLX 9850-4: 10 rack unit (RU) height X 17.22 inches (43.7 cm) width x 30 inches (76.2 cm) depth. Each chassis contains the following Field-replaceable units (FRUs): • Interface module (4 maximum) • Switch fabric module (SFM) (6 maximum) • Management modules (MM) (2 maximum) • Power supply assemblies (6 maximum) • Fan assemblies (3 maximum) SLX 9850-8: 17 rack unit (RU) height X 17.
Ethernet Ethernet System component Description QSFP28 ports The QSFP28 ports are available on 36-port 100GbE flex-speed interface module. The 36-port 100GbE interface modules supports 36-port 100GbE, 60-port 40GbE, or 240-port 10GbE and requires QSFP28 optics for connectivity. SFP+ ports The SFP+ ports are available on 72-port 10GbE/1GbE interface module. The 72-port 10GbE/1GbE interface module requires SFP+ ports for connectivity.
Weight and physical dimensions Other System component Description Serial Cable RJ-45 console cable RJ-45 connector Uses an RJ-45 connector for the serial port Weight and physical dimensions "Fully loaded" SLX 9850-4 device: 144 -100 Gig port configuration with four interface modules, including two management modules, six switch fabric modules, two fans, two power supplies, and two cable management combs.
Environmental requirements Card or module Description part number BRSLX9850-8-SFM Height Width Depth Weight (no optics) 1.835 in 23.47 in 5.78 in 5.22 kg 72-port 10GbE/ 1GbE interface module, part number BRSLX9850-10Gx72 S-M Interface module with 72 10GbE/ 1GbE ports (requires SFP+ optics) 64.0 mm 411 mm 376.386 mm 13.1 lb 2.52 in 16.18 inches 14.82 in 5.
Power consumption (maximum configuration) Power supply model Maximum output power rating (DC) Input voltage Input line frequency Maximum input current Input line protection Maximum inrush current BR-SLX9850DCPWR-3000 3000 W —48 VDC (nominal) —40-60 VDC (range) N/A 90 A Input fuse on —48 VDC input <70 A peak initial current surge or spike of <10 ms High Voltage AC (HVAC) 3000 W HV AC, 100V-120VAC.
Power consumption (modules) (typical configuration) Model name Power used in watts Minimum number of power supplies Notes SLX 9850-8 11492 4 200 VAC amps, watts, and BTU/hr are calculated with 0.98 power factor and 4 PSUs Power consumption (modules) (typical configuration) NOTE Typical configuration is 50% traffic with fans operating normally. Ambient temperature 25 deg C.
Serial port specifications (protocol) Data port specifications (Ethernet) Model Port type Number of ports Description SLX 9850-4 1 GbE 288 Supports up to 288 1-GbE ports with four 72-port 10GbE/1GbE interface modules 10 GbE 288 Supports up to 288 10-GbE ports with four 72-port 10GbE/1GbE interface modules 960 Supports up to 960 10-GbE ports with four 36-port 100GbE, 60-port 40GbE, or 240-port 10GbE flex-speed interface modules (requires 40GbE-to-10GbE breakout) 40 GbE 240 Supports up to 240
Memory specifications Parameter Value Flow control None Memory specifications Memory Type Size Non-volatile storage Solid-state drive (SSD) Management module: 2x256GB multi-level cell (MLC) Interface module: 1x128GB MLC Main memory SDRAM Management module: 16 GB DRAM Interface module: 16GB DRAM Regulatory compliance (EMC) • FCC Part 15, Subpart B (Class A) • EN 55022 (CE mark) (Class A) • EN 55024 (CE mark) (Immunity) for Information Technology Equipment • ICES-003 (Canada) (Class A) •
Regulatory compliance (environmental) • 30/2011/TT-BCT - Vietnam circular. • SJ/T 11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in EIPs (China). • SJ/T 11364-2006 Marking for the Control of Pollution Caused by EIPs (China).