Installation Guide
Table Of Contents
- Extreme SLX 9850-4 Router Hardware Installation Guide
- Preface
- About this Document
- Device Overview
- Preparing for the Installation
- Mounting the Device
- Initial Setup and Verification
- Initial setup and configuration checklist
- Items required
- Providing power to the device
- Establishing a serial connection
- Configuring a static IP address
- Establishing an Ethernet connection
- Customizing the chassis and host names
- Configuring the DNS service
- Setting the date and time
- Verifying correct operation
- Backing up the configuration
- Powering down the device
- Installing cable management kit
- Monitoring the Device
- Management Modules
- Interface Modules
- Power Supply Modules
- Power supply module overview
- Precautions specific to the power supply module
- Time and items required for removal and replacement
- Removing an AC power supply module
- Inserting an AC power supply module
- Removing a DC power supply module
- Inserting a DC power supply module
- Verifying power supply module operation
- High Voltage Power Supply Unit supporting AC and DC Voltages
- Fan Modules
- Switch Fabric Modules
- Transceivers and cables
- Supported transceivers and cables
- Time and items required
- Precautions specific to transceivers and cables
- Cleaning the fiber-optic connectors
- Managing cables
- Installing an SFP+ transceiver
- Replacing an SFP+ transceiver
- Installing a QSFP28 transceiver
- Replacing a QSFP28 transceiver
- Breakout cables
- Verifying transceiver operation
- Hardware Maintenance Schedule
- Brocade SLX 9850 Router Technical Specifications
- System specifications
- Ethernet
- LEDs
- Other
- Weight and physical dimensions
- Environmental requirements
- Power supply specifications (per PSU)
- Power consumption (typical configuration)
- Power consumption (maximum configuration)
- Power consumption (modules) (typical configuration)
- Power consumption (modules) (maximum configuration)
- Data port specifications (Ethernet)
- Serial port specifications (pinout RJ-45)
- Serial port specifications (protocol)
- Memory specifications
- Regulatory compliance (EMC)
- Regulatory compliance (safety)
- Regulatory compliance (environmental)
- Regulatory Statements
- Cautions and Danger Notices
TABLE 25 HV PSU (continued)
Input Voltage Air-ow Type Input Connector
HV AC, 100V-120V AC, 200V-277V AC
This PSU is 80+ platinum generating output DC power of 3000W for system usage.
The following gure shows the Input side of the 3000W HV PSU:
FIGURE 56 3000W HV PSU Input Side
1. OUTPUT LED
2. INPUT LED
3. Cover Plate
4. Handle
5. Input Plug SAFD-D
6. Latch of the PSU
The PSU supports one INPUT and one OUTPUT LED for status indication of PSU. The table below indicates the status LED color and
their meaning.
TABLE 26 HV PSU Status LED
Denitions
Type LED Denitions
Power supply LEDs
• LED 1 and LED 2: Steady Green - Input and output voltages
are within range
• LED 1: O and LED 2: Flashing Yellow - Power supply does
not have incoming power and is not providing power to the
device, or the Input AC voltage is out of range.
• LED 1: Green and LED 2: Yellow - Output voltage is out of
range
High Voltage Power Supply Unit supporting AC and DC Voltages
Extreme SLX 9850-4 Router Hardware Installation Guide
53-1004399-07 111