Installation Guide
Table Of Contents
- ExtremeRouting SLX 9850-8 Hardware Installation Guide
- Preface
- About this Document
- Device Overview
- Preparing for the Installation
- Mounting the Device
- Initial Setup and Verification
- Initial setup and configuration checklist
- Items required
- Providing power to the device
- Establishing a serial connection
- Configuring a static IP address
- Establishing an Ethernet connection
- Customizing the chassis and host names
- Configuring the DNS service
- Setting the date and time
- Verifying correct operation
- Backing up the configuration
- Powering down the device
- Installing cable management kit
- Monitoring the Device
- Management Modules
- Interface Modules
- Power Supply Modules
- Power supply module overview
- Precautions specific to the power supply module
- Time and items required for removal and replacement
- Removing an AC power supply module
- Inserting an AC power supply module
- Removing a DC power supply module
- Inserting a DC power supply module
- Verifying power supply module operation
- High Voltage Power Supply Unit supporting AC and DC Voltages
- Fan Modules
- Switch Fabric Modules
- Transceivers and cables
- Supported transceivers and cables
- Time and items required
- Precautions specific to transceivers and cables
- Cleaning the fiber-optic connectors
- Managing cables
- Installing an SFP+ transceiver
- Replacing an SFP+ transceiver
- Installing a QSFP28 transceiver
- Replacing a QSFP28 transceiver
- Breakout cables
- Verifying transceiver operation
- Hardware Maintenance Schedule
- ExtremeRouting SLX 9850 Technical Specifications
- System specifications
- Ethernet
- LEDs
- Other
- Weight and physical dimensions
- Environmental requirements
- Power supply specifications (per PSU)
- Power consumption (typical configuration)
- Power consumption (maximum configuration)
- Power consumption (modules) (typical configuration)
- Power consumption (modules) (maximum configuration)
- Data port specifications (Ethernet)
- Serial port specifications (pinout RJ-45)
- Serial port specifications (protocol)
- Memory specifications
- Regulatory compliance (EMC)
- Regulatory compliance (safety)
- Regulatory compliance (environmental)
- Regulatory Statements
- Cautions and Danger Notices
FIGURE 46 Port numbering for the ex-speed module when port speed is set to 10GbE or 40GbE
When the module is set to 100GbE, 36 of the 60 ports are active. The following gure shows you the active ports when the module is
set to 100GbE. The inactive ports are dimmed in the gure.
NOTE
You can also enter the chassis beacon enable command to determine the active ports. This command causes the LEDs
associated with the active ports to blink amber. To turn o the blinking LEDs, enter the chassis beacon disable command.
FIGURE 47 Port numbering for the ex-speed module when port speed is set to 100GbE
The following gure shows the front panel of the 72-port 10GbE/1GbE interface module.
FIGURE 48 Front panel - 72-port 10GbE/1GbE interface module
The following gure shows the port numbering for the 72-port 10GbE/1GbE interface module.
FIGURE 49 Port numbering for the 72-port 10GbE/1GbE interface module
For a description of the module LEDs, refer to Interpreting interface module LEDs on page 77.
Interface module overview
ExtremeRouting SLX 9850-8 Hardware Installation Guide
94 9035475-02 Rev AA