Installation Guide

Table Of Contents
Interface cards are enabled and optics/Trac are at full line rate. Random packets, fans at nominal speed, ambient temperature 40 deg
C.
Conguration of SLX 9850-8: One 8-slot chassis with two management modules, six switch fabric modules, twelve power supplies,
three fan modules, and eight 36-port 100GbE, 60-port 40GbE, or 240-port 10GbE ex-speed interface modules set in 60x40 mode.
Interface cards are enabled and optics/Trac are at full line rate. Random packets, fans at nominal speed, ambient temperature 40 deg
C.
Model name Power used in watts Minimum number of power
supplies
Notes
SLX 9850-4 5947 2 200 VAC amps, watts, and BTU/hr
are calculated with 0.98 power
factor and 2 PSUs
SLX 9850-8 11492 4 200 VAC amps, watts, and BTU/hr
are calculated with 0.98 power
factor and 4 PSUs
Power consumption (modules) (typical conguration)
NOTE
Typical conguration is 50% trac with fans operating normally. Ambient temperature 25 deg
C.
Module Typical power consumption
Management Module 97 W
Switch Fabric Module SLX 9850-4: 102 W
SLX 9850-8: 200 W
Fan module SLX 9850-4: 175 W
SLX 9850-8: 346W
72-port 10GbE/1GbE interface module 250 W
36-port 100GbE, 60-port 40GbE, or 240-port
10GbE ex-speed interface module
617 W
Power consumption (modules) (maximum
conguration)
NOTE
Maximum conguration is 100% trac with fans operating normally. Ambient temperature 40 deg
C.
Module Maximum power consumption
Management Module 100W
Switch Fabric Module SLX 9850-4: 124 W
SLX 9850-8: 220 W
Fan module SLX 9850-4: 175 W
Power consumption (modules) (typical conguration)
ExtremeRouting SLX 9850-8 Hardware Installation Guide
136 9035475-02 Rev AA