Installation Guide

Table Of Contents
TABLE 25 HV PSU Rating
Type Rated Input Voltage Supported Input Voltage Range
High Voltage DC (HVDC) 240V - 380VDC 192V-400VDC
High Voltage AC (HVAC) 100V - 120VAC, 200V - 277VAC 90V - 132VAC, 180-305VAC
Similar to the AC PSU that is already supported and released, the HV PSU have an integrated fan in it and therefore will need to match
airow of the PSU fan to the base chassis airow. There is only one air direction version and it will intake air from the port side and
exhaust to the non-port side. This PSU is oered to match airow of the chassis. In summary, following are two HV PSU oerings made
available for SLX 9850-4 SLX 9850-8.
TABLE 26 HV PSU
Input Voltage Air-ow Type Input Connector
HV DC, 240V-380V DC
&
HV AC, 100V-120V AC, 200V-277V AC
Intake - NPI SAF-D Type
This PSU is 80+ platinum generating output DC power of 3000W for system usage.
The following gure shows the Input side of the 3000W HV PSU:
FIGURE 56 3000W HV PSU Input Side
1. OUTPUT LED
2. INPUT LED
3. Cover Plate
4. Handle
5. Input Plug SAFD-D
6. Latch of the PSU
High Voltage Power Supply Unit supporting AC and DC Voltages
ExtremeRouting SLX 9850-8 Hardware Installation Guide
106 9035475-02 Rev AA