Installation Guide
Table Of Contents
- ExtremeRouting SLX 9850-4 Hardware Installation Guide
- Preface
- About this Document
- Device Overview
- Preparing for the Installation
- Mounting the Device
- Initial Setup and Verification
- Initial setup and configuration checklist
- Items required
- Providing power to the device
- Establishing a serial connection
- Configuring a static IP address
- Establishing an Ethernet connection
- Customizing the chassis and host names
- Configuring the DNS service
- Setting the date and time
- Verifying correct operation
- Backing up the configuration
- Powering down the device
- Installing cable management kit
- Monitoring the Device
- Management Modules
- Interface Modules
- Power Supply Modules
- Power supply module overview
- Precautions specific to the power supply module
- Time and items required for removal and replacement
- Removing an AC power supply module
- Inserting an AC power supply module
- Removing a DC power supply module
- Inserting a DC power supply module
- Verifying power supply module operation
- High Voltage Power Supply Unit supporting AC and DC Voltages
- Fan Modules
- Switch Fabric Modules
- Transceivers and cables
- Supported transceivers and cables
- Time and items required
- Precautions specific to transceivers and cables
- Cleaning the fiber-optic connectors
- Managing cables
- Installing an SFP+ transceiver
- Replacing an SFP+ transceiver
- Installing a QSFP28 transceiver
- Replacing a QSFP28 transceiver
- Breakout cables
- Verifying transceiver operation
- Hardware Maintenance Schedule
- ExtremeRouting SLX 9850 Technical Specifications
- System specifications
- Ethernet
- LEDs
- Other
- Weight and physical dimensions
- Environmental requirements
- Power supply specifications (per PSU)
- Power consumption (typical configuration)
- Power consumption (maximum configuration)
- Power consumption (modules) (typical configuration)
- Power consumption (modules) (maximum configuration)
- Data port specifications (Ethernet)
- Serial port specifications (pinout RJ-45)
- Serial port specifications (protocol)
- Memory specifications
- Regulatory compliance (EMC)
- Regulatory compliance (safety)
- Regulatory compliance (environmental)
- Regulatory Statements
- Cautions and Danger Notices
Card or module Description Height Width Depth Weight (no optics)
Management
module, part number
BR-SLX9850-MM
Management
module
54.5 mm
1.79 in
201.0 mm
7.91 in
376.386 mm
14.82 in
6.7 lb
3.04 kg
Switch fabric module
for SLX 9850-4,
part number BR-
SLX9850-4-SFM
Switch fabric module 46.6 mm
1.835 in
321.5 mm
12.66 in
146.823 mm
5.78 in
6.7 lb
3.04 kg
Switch fabric module
for SLX 9850-8,
part number BR-
SLX9850-8-SFM
Switch fabric module 46.6 mm
1.835 in
596.176 mm
23.47 in
146.823 mm
5.78 in
11.5 lb
5.22 kg
72-port 10GbE/
1GbE interface
module, part number
BR-
SLX9850-10Gx72
S-M
Interface module
with 72 10GbE/
1GbE ports (requires
SFP+ optics)
64.0 mm
2.52 in
411 mm
16.18 inches
376.386 mm
14.82 in
13.1 lb
5.94 kg
36-port 100GbE,
60-port 40GbE, or
240-port 10GbE
ex-speed interface
module, part number
BR-
SLX9850-100Gx3
6CQ-M
Interface module
with 36 100GbE
ports (requires
QSFP28 optics),
40GbE ports
(requires QSFP+
optics), or 240
10GbE ports
(requires 40GbE-
to-10GbE breakout)
64.0 mm
2.52 in
411 mm
16.18 inches
376.386 mm
14.82 in
22.1 lb
10.02 kg
Environmental requirements
Condition Operational Non-operational
Ambient temperature 0°C to 40°C (32°F to 104°F) outside device −25°C to 55°C (−13°F to 131°F) outside device
Relative humidity (non-
condensing)
5% to 95% 5% to 95%
Altitude (above sea level) 0 to 3000 m (10,000 feet) 0 to 12,000 m (40,000 feet)
Shock 5G, 11ms, half sine shock 10G, 10ms trapezoid shock
Vibration 0.2 G, 5-500 Hz at 1.0 octave/minute 0.5 G, 5-500 Hz at 1.0 octave/minute
Airow SLX 9850-4 - Maximum: 2336 cmh (1375 cfm)
SLX 9850-8 - Maximum: 4035 cmh (2375 cfm)
N/A
Heat dissipation Refer to values under "Power consumption (maximum
conguration)".
N/A
Environmental requirements
ExtremeRouting SLX 9850-4 Hardware Installation Guide
140 9035474-02 Rev AA