Installation Guide

Table Of Contents
SLX 9850-4 can accommodate up to 6 PSUs in 3+3 fully redundant PSU conguration. Both PSUs in the chassis must of same kind
i.e. both PSUs must be 240V AC PSUs or both PSUs must be High Voltage PSUs. Mixing of 240V AC and High Voltage PSUs in same
chassis is not supported.
NOTE
Mixing of Regular AC and HV PSUs in a single chassis is not supported.
NOTE
HV PSUs will be supported only on "build to order" base chassis SKU namely [Fusion Chassis P/Ns]. These oerings do not
include PSUs or Fans. PSUs and Fans must be added based on the customer power requirements. This arrangement allows
assembling chassis as per customer requirements (HV PSU or 240V AC PSU). No new base director chassis P/Ns will be
created that includes HV PSUs.
High Voltage Power Supply Unit supporting AC and DC Voltages
ExtremeRouting SLX 9850-4 Hardware Installation Guide
9035474-02 Rev AA 113