Technical Specs

Power supply model Maximum
output power
rating (DC)
Input voltage Input line
frequency
Maximum input
current
Input line
protection
Maximum inrush
current
BR-SLX9850-
DCPWR-3000
3000 W —48 VDC (nominal)
—40-60 VDC
(range)
N/A 90 A Input fuse on —48
VDC input
<70 A peak initial
current surge or
spike of <10 ms
High Voltage AC
(HVAC)
3000 W HV AC,
100V-120VAC.
200V-277VAC
High Voltage DC
(HVDC)
3000 W HV DC,
240V-380V DC
The weight of the power supply unit without packaging or boxes for BR-SLX9850-ACPWR-3000: 5.45lbs or 2.47kg
Component Blank Panel Weights
Component Weight (lbs) Weight (kgs)
Line Card 4.15 4.15
Management Module (MM) 2.10 0.95
SFM4 1.65 0.75
SFM8 2.85 1.29
Power Supply 0.60 0.27
Power consumption (typical conguration)
Conguration
of SLX 9850-4: One 4-slot chassis with one management module, ve switch fabric modules, two power supplies, three
fan modules, and four 36-port 100GbE, 60-port 40GbE, or 240-port 10GbE ex-speed interface modules set in 60x40 mode.
Interface cards are enabled and optics/Trac are at 50% line rate. Random packets, fans at nominal speed, ambient temperature 25 deg
C.
Conguration of SLX 9850-8: One 8-slot chassis with one management module, ve switch fabric modules, four power supplies, three
fan modules, and eight 36-port 100GbE, 60-port 40GbE, or 240-port 10GbE ex-speed interface modules set in 60x40 mode.
Interface cards are enabled and optics/Trac are at 50% line rate. Random packets, fans at nominal speed, ambient temperature 25 deg
C.
Model name Power used in watts Minimum number of power
supplies
Notes
SLX 9850-4 3958 2 200 VAC amps, watts, and BTU/hr
are calculated with 0.98 power
factor and 2 PSUs
SLX 9850-8 7773 4 200 VAC amps, watts, and BTU/hr
are calculated with 0.98 power
factor and 4 PSUs
Power consumption (typical conguration)
ExtremeRouting SLX 9850 Technical Specications
9035477-02 13