Technical Specs
Table Of Contents
- Brocade SLX 9850 Router Technical Specifications
- Preface
- Brocade SLX 9850 Router Technical Specifications
- System specifications
- Ethernet
- LEDs
- Other
- Weight and physical dimensions
- Environmental requirements
- Power supply specifications (per PSU)
- Power consumption (typical configuration)
- Power consumption (maximum configuration)
- Power consumption (modules) (typical configuration)
- Power consumption (modules) (maximum configuration)
- Data port specifications (Ethernet)
- Serial port specifications (pinout RJ-45)
- Serial port specifications (protocol)
- Memory specifications
- Regulatory compliance (EMC)
- Regulatory compliance (safety)
- Regulatory compliance (environmental)
Ethernet
System component Description
QSFP28 ports The QSFP28 ports are available on 36-port 100GbE ex-speed interface module. The 36-port 100GbE
interface modules supports 36-port 100GbE, 60-port 40GbE, or 240-port 10GbE and requires QSFP28
optics for connectivity.
SFP+ ports The SFP+ ports are available on 72-port 10GbE/1GbE interface module. The 72-port 10GbE/1GbE interface
module requires SFP+ ports for connectivity.
Management RJ-45 port The management RJ-45 port on the MM management interface labeled MANAGEMENT for 1G/100M/10M
connectivity.
Service RJ-45 port The service RJ-45 port on the MM service interface labeled SERVICE for 10G/1G/100M connectivity
LEDs
System component Description
Interface module LEDs
• Power: Green - Power OK, o - No power
• Status: Green- Status OK, Amber - Error; O - Unexpected error
• Link status (1 LED per physical port): Green (Solid) - Link is up; Green (Blinking) - Link is up and
running trac; O - No link
Management module LEDs
• Power: Green - Power OK, o - No power
• Status: Green- Status OK, Amber - Error, O - Unexpected error
• Active: O - This management module is in Standby mode; Blue - This is the active management
module.
• Switch fabric module status: Green - switch fabric module OK; Amber - error; O - Unexpected error
• Ethernet: Green (Solid) - Link is up; Green (Blinking) - Link is up and running trac; O - No link;
Amber (some ex module ports): module is in 100G mode and these ports are inactive
Switch fabric module LEDs
• Power: Green - Power OK; o - No power
• Switch fabric module status: Amber - Error
NOTE
There is a switch fabric module status LED on the front panel of the Fan module.
Power supply LEDs
• LED 1 and LED 2: Steady Green - Input and output voltages are within range
• LED 1: O and LED 2: Flashing Yellow - Power supply does not have incoming power and is not
providing power to the device, or the Input AC voltage is out of range.
• LED 1: Green and LED 2: Yellow - Output voltage is out of range
• LED 1: Green and LED 2: Flashing Yellow/Green - Over-temperature warning or fan error
Fan module LEDs
• Power (Fan) LED: No light (LED is o) - Fan assembly does not have power. Steady green - Fan
assembly has power.
• Status (Fan) LED: No light (LED is o) - Fan assembly is either healthy or does not have power. Steady
amber - Fan assembly is being initialized or has a failure (full or partial).
• Power (SFM) LED: No light (LED is o) - One or more SFM module is not powered on. Green -
Module is operational.
• Status (SFM) LED: No light (LED is o) - One or more SFM module is either not operational or does
not have power. Amber - Module is faulty or initializing. Green - Module is operational.
NOTE
Since the switch fabric module is behind the fan, the fan contains an LED that indicates
problems with one of the switch fabric modules behind the fan.
Ethernet
Brocade SLX 9850 Router Technical Specications
8 53-1005278-01