Sentriant AG200 Hardware Installation Guide Extreme Networks, Inc. 3585 Monroe Street Santa Clara, California 95051 (888) 257-3000 (408) 579-2800 http://www.extremenetworks.com Published: June 2008 Part number: 100317-00 Rev.
AccessAdapt, Alpine, Altitude, BlackDiamond, EPICenter, ESRP, Ethernet Everywhere, Extreme Enabled, Extreme Ethernet Everywhere, Extreme Networks, Extreme Standby Router Protocol, Extreme Turbodrive, Extreme Velocity, ExtremeWare, ExtremeWorks, Essentials, ExtremeXOS, the Go Purple Extreme Solution, ScreenPlay, Sentriant, ServiceWatch, Summit, SummitStack, Triumph, Unified Access Architecture, Unified Access RF Manager, UniStack, the Extreme Networks logo, the Alpine logo, the BlackDiamond logo, the Extreme
Contents Preface........................................................................................................................................... 5 About this Guide .........................................................................................................................5 Organization of this Guide............................................................................................................5 Conventions...................................................................
Contents Appendix B: Technical Specifications ............................................................................................ 35 Index ............................................................................................................................................
Preface This preface provides an overview of this guide, describes guide conventions, and lists other publications that might be useful. About this Guide This guide describes how to install the Sentriant AG200 appliance in an equipment rack.
Preface Table 2: Text Conventions Convention Description Screen displays or entered text This typeface represents information as it appears on the screen, command syntax, or text you enter on a command line. The words “enter” and “type” When you see the word “enter” in this guide, you must type something, and then press the Return or Enter key. Do not press the Return or Enter key when an instruction simply says “type.
1 About the Sentriant AG200 Appliance This chapter includes the following sections: ● “Chassis Overview” on page 7 ● “Front Panel Features” on page 7 ● “Back Panel Features” on page 8 ● “LED Operation” on page 8 ● “LCD Panel” on page 9 Chassis Overview The Sentriant AG200 appliance is a compact enclosure that is 1 RU (1.75 inches) high. It fits into a standard 19-inch (48.26 cm) rack. The Sentriant AG appliance provides two 10/100/1000 Ethernet ports, a serial console port, and a USB port.
About the Sentriant AG200 Appliance Back Panel Features Figure 2 shows the back panel of the Sentriant AG appliance. Figure 2: Back Panel of the Sentriant AG Appliance Reset switch Power switch AC power connector SN_002 The back panel of the Sentriant AG appliance has the following features: ● AC power input connector ● Power switch ● Reset switch LED Operation The LCD panel on the Sentriant AG appliance includes two LEDs labeled Power and HDD.
LCD Panel The LCD panel on the Sentriant AG appliance provides identifying information for the appliance and information about the basic system health.
About the Sentriant AG200 Appliance 10 Sentriant AG200 Hardware Installation Guide
2 Site Preparation and Unpacking This chapter includes the following sections: ● “Site Requirements for the Sentriant AG Appliance” on page 11 ● “Unpacking the Sentriant AG Appliance” on page 12 Site Requirements for the Sentriant AG Appliance The Sentriant AG200 appliance can be rack-mounted in a standard 19-inch rack. Locate the system away from heat sources and in an area that provides unobstructed air flow to the chassis cooling vents.
Site Preparation and Unpacking Unpacking the Sentriant AG Appliance When you unpack the Sentriant AG appliance, verify that you have received the following items: 12 ● Extreme Networks Sentriant AG appliance ● Two rack-mounting brackets ● Eight Phillips screws (two extras) for attaching the rack-mounting brackets to the unit ● AC power cord for use in North America ● DB-9-to-RJ-45 serial cable for connecting the serial console port ● Sentriant AG200 Hardware Quick Start Guide ● Registration
3 Installing the Sentriant AG200 Appliance This chapter includes the following sections: ● Overview on page 13 ● Required Tools and Equipment on page 13 ● Attaching the Rack-Mount Brackets on page 13 ● Installing the Sentriant AG Appliance in a Rack on page 14 ● Connecting Power on page 15 ● Connecting Cables on page 15 Overview The Sentriant AG200 appliance fits into a standard 19-inch (48.26 cm) rack.
Installing the Sentriant AG200 Appliance 3 Repeat these steps to attach the other bracket to the opposite side of the Sentriant AG appliance. Figure 3: Attaching Rack-Mount Brackets SN_003 Installing the Sentriant AG Appliance in a Rack To install the Sentriant AG appliance in a rack: 1 Determine the mounting location for the Sentriant AG appliance. 2 Slide the Sentriant AG appliance into the rack and secure the mounting brackets to both front posts using screws appropriate to the rack.
Connecting Power Connect the AC power cable from the power connector on the back of the Sentriant AG appliance to an active power outlet. To power on the Sentriant AG appliance, press the power switch to the On position.
Installing the Sentriant AG200 Appliance 16 Sentriant AG200 Hardware Installation Guide
4 Startup and Configuration The Sentriant AG200 appliance is shipped with the latest software installed. You must connect to the server using the console port on the front panel to configure the Sentriant AG appliance for your network with the correct IP address, default gateway, DNS server, and other settings.
Startup and Configuration 5 Select Yes to save the changes or No to discard the changes. A confirmation message is displayed for either action. If you save the changes, you must reboot the system for the changes to take effect. To perform the initial setup process, see the next section. Performing the Initial Setup After you have changed the default password, perform the initial setup.
3 Edit the IP address, Netmask, Default Gateway, Hostname, and DNS Server fields. 4 Select OK and save the changes. Setting the Time, Date, and Time Zone To set the time, date, and time zone: 1 From the main configuration menu, highlight Adjust time, date, timezone, and select OK. 2 Press [Enter]. The main time and date configuration menu is displayed. 3 To set the date and time: a Highlight Change the date and time and press [Enter].
Startup and Configuration b Change the date and select OK. c Change the time and select OK. 4 Confirm the change and save the changes. 5 Select OK to return to the time/date/timezone menu. 6 To change the time zone: a Highlight Change your timezone and select OK. Press [Enter].
b Scroll down to highlight the appropriate timezone and press [Enter] to select the highlighted timezone. Then tab to OK and press [Enter]. c Confirm the change and save the changes. d Select OK to return to the time/date/timezone menu. 7 To change the NTP server: a Highlight Change or edit the NTP server list and select OK. Press [Enter]. A comma-separated list of NTP server names is displayed. b Change or edit the server names and select OK. Press [Enter]. c Select Yes to accept the list of servers.
Startup and Configuration Setting the Operation Mode of the Server To set the operation mode (personality) of the server: 1 From the main menu, highlight Set personality of the Sentriant AG. A warning message is displayed. 2 Select Yes to display the personality selection menu. 3 Highlight the appropriate server type (Management Server, Enforcement Server, or Combination Server) and press the space bar. A confirmation dialog box is displayed. 4 If the displayed server type is correct, select Yes.
Initial Configuration NOTE If endpoints are already attached to a switch when you install Sentriant AG, you must log in to each switch and send the NAC revalidate command before the endpoint can be tested and routed properly. To configure the Sentriant AG appliance: 1 Log in to a different computer with browser software installed. The following browsers are supported for this release: ● Windows: IE 6.0 or later, Mozilla Firefox v1.5 or later, Mozilla v1.7 ● Linux: Mozilla Firefox v1.
Startup and Configuration 4 Respond to the Accept license agreement window in one of the following ways: ● If you do not wish to accept the license agreement, select I do not accept this license agreement. or ● Read the Sentriant AG End-User License Agreement and select I Accept this license agreement. 5 Click Next. The Enter management server settings window opens.
8 If you use a proxy server, select Use a proxy server for Internet connections. (Connecting to the Internet is necessary for updating tests, validating license keys, and sending support packages.) Configure the following parameters for the proxy server: ● Proxy server IP address: IP address of the server that will act as the proxy for Internet connections. ● Proxy server port: Port used for connecting to the proxy server (for example, 8080).
Startup and Configuration CAUTION If you use a proxy server, your license key will not validate from this window unless you have performed step 8 on page 25. 11 Enter a User name and Password for the initial Sentriant AG administrator account. (This is not the same as the server’s root account that you created in during installation.) We suggest the password be at least eight characters with a mix of numbers and letters. Click Finish. The Sentriant AG home window opens.
3 Use the arrow keys to highlight Integrated Peripherals, and press [Enter}. 4 Select Onboard Devices.
Startup and Configuration 5 Select Lan 1/2 power on bypass and select Enabled. Select PWR On/Off Lan Bypass Ctrl and select Enabled. 6 Press [Esc] twice to return to the main menu.
A Safety Information WARNING! Read the following safety information thoroughly before installing Extreme Networks products. Failure to follow this safety information can lead to personal injury or damage to the equipment. Only trained service personnel should perform service to Extreme Networks equipment and their components.
Safety Information WARNING! Provided with this product is a detachable power supply cord with IEC320 style terminations for use in the US. Before making the connection, make sure the voltage rating of the product equals or exceeds the voltage and amperage rating of the power source. For 120-volt applications, use only a UL-listed detachable power cord with a NEMA configuration 5-15P type (parallel blades) plug cap.
Battery Replacement and Disposal The lithium battery in this equipment is not user-replaceable. It must be replaced by qualified Extreme Service personnel only. Contact your Extreme Service personnel for product replacement. Do not attempt to replace the battery.
Safety Information Sicherheitshinweise WARNUNG! Vor der Installation der Produkte von Extreme Networks sind die nachfolgenden Sicherheitshinweise aufmerksam zu lesen. Die Nichtbeachtung dieser Sicherheitshinweise kann zu Verletzungen oder Schäden an der Ausrüstung führen.
Warnhinweise ● Das System an vorschriftsmäßig geerdete Steckdosen anschließen, um die Gefahr elektrischer Schläge zu vermeiden. Die Steckdose muss in der Nähe der Anlage installiert und leicht zugänglich sein, um eine schnelle Trennung vom Netz zu ermöglichen. ● Sicherstellen, dass Spannung und Frequenz der Steckdose den elektrischen Nenndaten des Systems entsprechen. Das Gebäude bzw. die Stromquelle muss mit einem Überlastschutz ausgestattet sein.
Safety Information ● Verlegen von Kabeln: Kabel so verlegen, dass keine Schäden entstehen oder Unfälle, z. B. durch Stolpern, verursacht werden können. ● Bei einer Installation in einem Gestell darauf achten, dass schwere Geräte unten im Gestell eingebaut werden, um Gefahren durch Umkippen zu vermeiden. Austauschen und Entsorgen von Batterien ● 34 Austauschen der Lithium-Batterie: Die Batterie kann nicht vom Anwender ausgetauscht werden.
B Technical Specifications Table 4 provides technical specifications for the Sentriant AG200 appliance. Table 4: Sentriant AG Appliance Technical Specifications Physical Specifications Chassis dimensions Height: 1.7 inches (4.3 cm) Width: 17 inches (43.2 cm) Depth: 17.3 inches (43.9 cm) Weight 21 lb (9.5 kg) Power Input Voltage ranging 90-254 V AC Nominal voltage range: 100-240 V AC Line frequency range 47-63 Hz Maximum input current 2.4A @ 100 V AC 1.
Technical Specifications Table 4: Sentriant AG Appliance Technical Specifications (Continued) European EMC for ITE 89/336/EEC EMC Directive EN 55022:1998 A2:2003 Class A EN55024:1998 A2:2003 includes IEC/EN61000-2,3,4,5,6,11 EN61000-3-2:2000 Class A (Harmonics) EN61000-3-3:1995 A1:2001 (Flicker) ETSI/EN 300 386:v1.3.
Table 4: Sentriant AG Appliance Technical Specifications (Continued) Storage and transportation conditions (packaged) Temperature*: –40º C to +70º C (–40º F to 158º F) Relative humidity*: 10–93% RH Shock*: 180 m/s2 (18g), 6ms600 shocks (package < 50 kg) Random vibration*: 5–20 Hz @ 1.0 ASD w/–3 dB/oct. from 20–200 Hz Sinusoidal vibration: 5–62 Hz @ Velocity 5 mm/s, 62–500 Hz @ .2G Drop*: 42.4 * Short-term test condition. Not for extended use under this condition.
Technical Specifications 38 Sentriant AG200 Hardware Installation Guide
Index A P ambient temperature, 11 package contents, 12 physical specifications, 35 power connecting, 15 power cord selection, 29 power safety, 29 power specifications, 35 B battery disposal requirement, 31 C cable routing, 30 connecting power, 15 conventions notice icons, 5 text, 6 D dimensions, 35 E EMI/EMC standards, 35 enclosed rack requirements, 11 environmental requirements, 11 environmental specifications, 36 ESD protection, 30 R rack installation procedure, 14 requirements environmental, 11