Specifications

Clarifications, Known Behaviors, and Resolved Issues
Ridgeline Service Advisor Release Note28
Error when disabling EAPS primary port if EAPS ring was displayed in the Map View
If the primary port in an EAPS node was disabled while the EAPS ring was displayed in the Ridgeline
SA Map View, it resulted in an IllegalArgumentException error. (PD4-707645154)
Updated EAPS information not displayed in the Table View
When the status of an EAPS domain changed, the updated information was displayed in the Map View,
but not the Table View. (PD4-709785677)
Invalid Session message displayed when saving a map
If the Ridgeline SA server is experiencing network connectivity problems, such as dropped packets, it
may result in an “Invalid Session” message displayed on a remote client attempting to save a map view.
(PD4-988967106)
Alarm Manager
HTTP unreachable alarms not generated for certain devices
HTTP unreachable alarms were not generated for devices that had their HTTP services disabled prior to
when the HTTP unreachable alarm was configured and enabled. (PD4-699276054)
Incorrect Power Supply Failed alarm generated for SNMP-unreachable devices
Ridgeline SA incorrectly generated a Power Supply Failed alarm when a device was SNMP
unreachable. (PD4-788565691)
CPU Utilization threshold comes back after being deleted
In Alarm Manager, if you deleted the CPU Utilization threshold for a device, the next time the device
was synchronized, the CPU Utilization threshold for the device was again visible in the Alarm Manager.
(PD4-938840527)
Configuration Manager
Downloading a config file to device fails if using SSH
Downloading a configuration file to a device running ExtremeWare may fail if Ridgeline SA attempts to
use SSH to the device. If this occurs, to successfully download a configuration through Ridgeline SA,
you must temporarily disable SSH for the device. (PD3-102888481)