User guide

Packet Over SONET Module Installation and User Guide 2-13
Troubleshooting
Fixing Configuration Errors
If the STATUS LED on the PoS module turns amber and blinks, use the show slot
command to display the configured slot type. The output from this command also
displays information about the module state, including the CARD MISMATCH
message. This message indicates that the slot was previously configured for a module
type different than the one you just installed.
Use one of the following commands to reset the slot configuration:
clear slot <slot>
unconfig slot <slot>
config slot <slot> module [f32t | f32f | f48t | g4x | g6x | g8x |
g12x | p3c | p12c]
The first two commands listed above clear the slot of a previously assigned
module type. The third command replaces the existing module type configuration
with a new module type configuration.
Port x Green
Green blinking
Amber blinking,
returning to green
Amber blinking
Off
Link up
1
Link disabled
Activity on link
Link down; SONET link problem
No received signal
(No action required.)
See Fixing Link Down
Problems on page 2-15.
(No action required.)
See Fixing Link Down
Problems on page 2-15.
See Fixing Link Down
Problems on page 2-15.
1. The link is up, but the PPP/VLAN interface might not be up. To determine whether PPP is up, use the
show ppp command to display PPP status information (see the command description on page 3-27).
Table 2-1: PoS Module and Port LEDs (continued)
LED Color Indicates Corrective action