3-102 Packet Over SONET Module Installation and User Guide
Configuring the PoS Module
Configuring Port Attributes
The following ExtremeWare port commands are not supported for the PoS module:
•
show ports {<portlist>} collisions
• config ports <portlist> auto off {speed [10 | 100 | 1000]}
duplex [half | full]
• config ports <portlist> auto on
• enable smartredundancy <portlist>
• enable sharing <port> grouping <portlist> {port-based | address-based
| round-robin}
• enable mirroring to <port>
• disable learning ports <portlist>
• config mirroring add [vlan <name> | port <port> |
vlan <name> ports <portlist>]
Except as described below, the PoS module supports the remainder of the ExtremeWare
port commands. Table 3-18 describes the changes to the ExtremeWare port commands to
support the PoS module. Commands with keywords or parameters shown in italic
typeface are existing ExtremeWare commands that have been enhanced to support the
PoS module.
reboot {time <date> <time> | cancel}
{slot <slot>}
Enhanced command: The slot <slot> option was
added to the command to make it possible to
reboot a module in a specific slot. When you
specify this option, the command applies to the
PoS module in the specified slot, rather than to
the switch.
clear counters Augmented implementation: For the PoS
module, this command clears statistics for all of
the PoS-related functions: SONET, PPP,
NetFlow, DiffServ, and APS.
show diagnostics {<slot>} Augmented implementation: This command
displays the result of PoS module diagnostics.
run diagnostics [normal | extended] <slot> Enhanced command: This command runs the
PoS module diagnostics.
Table 3-17: Changes to General Switch Commands (continued)
Command Description of Change