Specifications
3
WWW.EXTREMENETWORKS.COM
• EN 60950-1 Safety of Information
Technology Equipment
• EN 60825-1 Safety of Laser Products —
Part 1: Equipment Classification
• Requirements and User’s Guide
• EN 60825-2 Safety of Laser Product —
Part 2: Safety of Optical Fibre Communication Systems
Electromagnetic Emission
• ICES-003 Electromagnetic Emission
• FCC Class A
• EN 55022/CISPR-22 Class A/VCCI Class A
• AS/NZS 55022, EN 61000-3-2 Power Line Harmonics
• EN 61000-3-3 Voltage Fluctuation and Flicker
• EN 61000-6-3 Emission Standard
(supersedes EN 50081-1)
Immunity
• EN 61000-6-1 Generic Immunity and Susceptibility
(supersedes EN 50082-1)
• EN 55024 Immunity Characteristics. Supersedes:
- EN 61000-4-2 ESD
- EN 61000-4-3 Radiated, radio frequency,
electromagnetic field
- EN 61000-4-4 Electrical fast transient
- EN 61000-4-5 Surge
- EN 61000-4-6 Conducted disturbances induced by
radio-frequency fields
- EN 61000-4-8 Power frequency magnetic field
- EN 61000-4-11 Voltage dips and sags
TELCO NEBS/ETSI
Designed to meet the following specifications (formal
testing under way):
• Telcordia GR-63-CORE NEBS Requirements: Physical
Protection
• Telcordia GR-1089-CORE EMC and Electrical Safety
• Telcordia SR-3580 Level 3
• •ETSI ETS 300-019 Physical Protection:
- Part 1-1, Class 1.1, Partly Temperature
Controlled Storage Locations
- Part 1-2, Class 2.3, Public Transportation
- Part 1-3, Class 3.1 Temperature Controlled
Locations (Operational)
• ETSI ETS 300-386 EMI/EMC
Specifications
Network Management
• Extreme Networks Advisor Web-based
Graphical User Interface (GUI)
• Integrated industry-standard Command Line
Interface (CLI)
• sFlow (RFC 3176)
• Telnet
• SNMP v1, v2c, v3
• SNMP MIB II
• RMON
• Support for automated configuration
management using NETCONF
• Entity MIB (Version 3)
Element Security Options
• TLS 1.1 and 1.2
• AAA
• RADIUS
• Secure Shell (SSH v2)
• Secure Copy (SCP v2)
• HTTPs, TACACS/TACACS+
• Username/Password (Challenge and Response)
• Bi-level Access Mode (Standard and EXEC Level)
• Protection against Denial of Service (DoS) attacks, such
as TCP SYN or Smurf Attacks
Environmental
• Operating temperature: 0°C to 40°C (32°F to 104°F)
• Storage temperature: -25°C to 70°C (-13°F to 158°F)
• Relative humidity: 5% to 90%, at 40°C (104°F), non-
condensing
• Storage humidity: 95% maximum relative humidity, non-
condensing
• Operating altitude: 6,600 feet (2,012 meters)
• Storage altitude: 15,000 feet (4,500 meters) maximum
Safety Agency Approvals
• CAN/CSA-C22.2 No. 60950-1-3
• UL 60950-1
• IEC 60950-1