Specifications

66 ExtremeWare 7.1.1 Release Notes
Clarifications, Known Behaviors, and Resolved Issues
SNMP
Adding or deleting a trapreceiver now detects the correct community string (1-9I5LD).
You can now configure the same community string for both read-only and read-write (PD2-118578301).
Troubleshooting
Output from the show diagnostics command now clearly states the number of recoverable and
non-recoverable errors found (PD2-142201419).
When a new threshold is configured for reboot loop protection, the time stamp is now cleared
(PD2-109830745).
If you configure a large reboot loop protection threshold, you can now configure a count of one
(PD2-111222216, PD2-111201401).
If you use SNMP or RMONII to issue the
reboot command, and reboot loop protection is configured
with a threshold of 1, the switch will reboot into minimal mode (PD2-111307101).
The
show diagnostics backplane-utilization command is no longer available on Alpine or
Summit switches. There are no backplane utilization diagnostics available for Alpine or Summit
switches (PD2-130597218).
If you configure the
card-down option in the configure sys-health-check command and checksum
errors are detected, the MSM is now taken offline as expected (PD2-105991401).