Specifications
58 ExtremeWare 7.1.1 Release Notes
Clarifications, Known Behaviors, and Resolved Issues
Packet Diagnostics Display Wrong Slot Name
When you run packet diagnostics on the MSM in slot B, the console displays the slot as slot 10, instead
of MSM-B. The display is wrong: the diagnostics are correctly running on the MSM in slot B. The
extended diagnostics console display is correct (PD2-138607801).
Bus-Stats Error Messages
The show config detail command output displays the following new commands:
disable bus-stats
configure bus-stats window history 3
configure bus-stats window errors 3
configure bus-stats threshold slow-path x
configure bus-stats threshold fast-path y
The bus-stats feature helps filter erroneous log messages related to transient hardware errors. It is
disabled by default and should only be enabled when troubleshooting transient hardware errors.
Enabling this feature requires activation by Extreme Networks personnel.
Spurious Message When system-down is Configured
If you configure the system health check alarm level for system-down and a fault is detected, the switch
is turned off but continuously logs the message “Card in slot N is off line.” You can ignore this message
(PD2-129386201).
The use configuration Command
When the switch is in minimum mode, the use configuration command has no effect on the backup
MSM (PD2-129133801).
Output of the show diagnostics Command
The output of the show diagnostics command for the CPU system might display negative numbers,
and the totals might not add up properly (PD2-128460401).
Configure Auto-Recovery to online or Alarm-Level to traps
If you configure the system health check auto-recovery to offline, save the configuration, and
configure the alarm-level to
log, a health check brings the module or switch offline regardless of how
many errors the health check detects. To avoid this, either configure auto-recovery to
online, or
configure alarm-level to
traps (PD2-124368101).
Error Count Not Accurate
If the switch is flooded with heavy traffic for more than 10 minutes, the CPU System field in the show
diagnostics
output is not accurate. The display reports up to 20 more errors (PD2-122738701).
Configuring Diagnostics Mode Off
If you configure diagnostics mode OFF, and then execute the unconfigure switch all command,
when the switch returns to active state the diagnostics mode is still set to OFF. The default diagnostics
mode should be
fastpost. To verify which diagnostics mode is set for the switch, use the show switch
command (1-97NL1).