Specifications
Clarifications and Known Behaviors
ExtremeWare 7.1.1 Release Notes 57
Extreme Power Supply Traps
A new object was added “extremePowerSupplyNumber” to the power supply traps. The two RPS traps
will no longer be sent out. Instead the extremePowerSupplyGood and extremePowerSupplyFail traps
will contain the power supply number indicating which power supply has failed (1-7J56T).
DHCP
The DHCP server is not supported as a standalone feature. It is used as part of the Network Login
feature only (1-8SAI6).
Diagnostics and Troubleshooting
Event Condition Command Completion
If you enter an event condition using the show log events command, press the [Tab] key for
command completion, the console displays an “Ambiguous token” message even though the event
condition exists. This occurs when there are additional conditions that also match your entry. If you
press [Return], the correct log is displayed. For example, if you enter
show log events
BGP.Damp.Cfgchg
and press [Tab], the console displays the following (PD2-153433301):
Ambiguous token: BGP.Dampening.CfgChg
<event condition>
"BGP.Dampening.CfgChg", "BGP.Dampening.CfgChgNullDinfo",
"BGP.Dampening.CfgChgNullNew", "BGP.Dampening.CfgChgNullOld",
"BGP.Dampening.CfgChgRt"
Entering q Does Not Quit Diagnostics Display
Entering q to quit the show diagnostics sys-health-check display does not quit the display
(PD2-145117543).
Single MSM Not Taken Offline
If you have only one MSM installed in a BlackDiamond chassis, you configure the system health check
alarm level to
card-down, and eight errors are detected, the MSM is not taken offline. The MSM remains
fully operational (PD2-143167301).
Automatic Memory Scanning Can Trigger Incorrect Reboot Loop Detection
On Summit and Alpine switches, if memory scanning is automatically initiated via the auto-recovery
parameter in the
configure sys-health-check command and the reboot loop detection threshold is 1,
the system might incorrectly detect a reboot loop and come up in minimal mode (PD2-140185601).
Packet Diagnostics Display Backplane Incorrectly
When you run packet diagnostics on the Alpine 3804, the console displays the backplane as slot 5. The
display is wrong: the diagnostics are correctly running on the backplane. The extended diagnostics
console display is correct (PD2-151752701).