Specifications

36 ExtremeWare 7.1.1 Release Notes
Clarifications, Known Behaviors, and Resolved Issues
BlackDiamond 6816 MIB Value for Input Power Voltage
On the BlackDiamond 6816, the extremeInputPowerVoltage attribute in extremeSytemCommonInfo is
shown as “0” and the extremePowerSupplyInputVoltage in the extremePowerSupplyTable is shown as
“unknown.” These values cannot be obtained from the switch (1-841J1).
Alpine
Limited Commands Mode
When in limited commands mode, the slot status LED remains orange, though the link is taken down
(PD2-99107226).
VDSL Modules in a Half-Duplex Link
A VDSL CPE operating in a half-duplex link can lock up when used with a hub and running wire-rate
randomized traffic. This is a hardware limitation. A restart of the VDSL port will recover, but if the
traffic continues at wire-rate and is randomized, then the problem will reoccur (PD2-71538118).
Summit
Output of the show log Command
The most common reason for transceiver diagnostics failure is heat. Thus the show log output displays
the TRXDIAG tag in the temperature log message (PD2-147462529).
The unconfigure switch all Command Clears the Default VLAN from s0
After you reset the switch to the factory defaults using the unconfigure switch all command, s0
does not contain the default VLAN. To add the default VLAN to s0, delete then add all ports in the
default VLAN (PD2-143709201).
Health Check Error Messages
Error messages from the system health check display the incorrect location (PD2-110132842).
Table 10: Memory scanning and mapping support in BlackDiamond modules
Module Memory Scanning and Mapping
F32Fi Yes
F48Ti Yes
F96Ti Yes
G12SXi Yes
G8Ti Yes
G8Xi Yes
WDMi Yes
MSM-3 Yes
MSM64i Yes