Technical Specs

Model Height Width Depth Weight
CER 2000 Series 2024F
with 2x10G uplink installed
4.4 cm
1.7 inches
44.3 cm
17.4 inches
44.8 cm
17.6 inches
7.9 kg
17.5 lb
Environmental requirements
Condition Operational Non-operational
Ambient temperature 0°C to 40°C (32°F to 104°F) -25°C to 70°C (-13°F to 158°F)
Relative humidity (non-
condensing)
5% to 95% at 40°C (104°F) 95% maximum
Altitude (above sea level) 3000 m (10,000 feet) 4500 m (15,000 feet)
Shock N/A N/A
Vibration N/A N/A
Airow 267 lfm N/A
Operating noise < 60 dB N/A
Power supply specications (per PSU)
Power supply
model
Maximum output
power rating (DC)
Input voltage Input line
frequency
Maximum input
current
Input line
protection
Maximum inrush
current
RPS9 504 W 100 - 240 VAC
(nominal)
85 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz (range)
6 A Line Fused 30 A peak @ 25°C
RPS9DC 504 W 48 VDC (nominal)
40 - 60 VDC
(range)
N/A 15 A -Ve Fused 25 A peak @ 25°C
Power consumption (idle conguration)
Idle: No optics or connections to ports installed and system booted up. Fans at nominal speed.
Model name @100 VAC input @200 VAC input @-48 VDC input Minimum number of
power supplies
Notes
BR-CES-2024C-4X
with 4x10G Uplink AC
& DC
1.64 A
184 W
628.79 BTU/hr
0.86 A
182 W
619.30 BTU/hr
2.96 A
158 W
540.63 BTU/hr
1 Input current only 1
PSU installed. Watts
and BTU/hr with 2
PSUs.
BR-CES-2024C-4X
AC & DC
1.64 A
184 W
628.79 BTU/hr
0.86 A
182 W
619.30 BTU/hr
2.96 A
158 W
540.63 BTU/hr
1 Input current only 1
PSU installed. Watts
and BTU/hr with 2
PSUs.
Power consumption (idle conguration)
ExtremeSwitching CES/CER 2000 Series Technical Specications
53-1003423-03 7