Environmental
Operating temperature: 0°C to 40°C (32°F to 104°F)
Storage temperature: –25°C to 70°C (–13°F to 158°F)
Relative humidity: 5% to 90%, at 40°C (104°F), non-condensing
Storage humidity: 95% maximum relative humidity, non-condensing
Operating altitude: 6,600 ft (2,012 m)
Storage altitude: 15,000 ft (4,500 m) maximum
Safety Agency Approvals
CAN/CSA-C22.2 No. 60950-1-3
UL 60950-1
IE C 60950-1
EN 60950-1 Safety of Information Technology Equipment
EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification,
Requirements and User’s Guide
EN 60825-2 Safety of Laser Product—Part 2: Safety of Optical Fibre
Communication Systems
Electromagnetic Emission
ICES-003 Electromagnetic Emission
FCC Class A
EN 55022/CISPR-22 Class A/VCCI Class A
AS/NZS 55022
EN 61000-3-2 Power Line Harmonics
EN 61000-3-3 Voltage Fluctuation and Flicker
EN 61000-6-3 Emission Standard (supersedes EN 50081-1)
Immunity
EN 61000-6-1 Generic Immunity and Susceptibility (supersedes
EN 50082-1)
EN 55024 Immunity Characteristics. Supersedes:
EN 61000-4-2 ESD
EN 61000-4-3 Radiated, radio frequency, electromagnetic field
EN 61000-4-4 Electrical fast transient
EN 61000-4-5 Surge
EN 61000-4-6 Conducted disturbances induced by
radiofrequency fields
EN 61000-4-8 Power frequency magnetic field
EN 61000-4-11 Voltage dips and sags
TELCO NEBS/ETSI
Designed to meet the following specifications (formal testing
under way):
Telcordia GR-63-CORE NEBS Requirements: Physical Protection
Telcordia GR-1089-CORE EMC and Electrical Safety
Telcordia SR-3580 Level 3
ET SI ET S 300-019 Physical Protection
Part 1-1, Class 1.1, Partly Temperature Controlled Storage Locations
Part 1-2, Class 2.3, Public Transportation
Part 1-3, Class 3.1, Temperature Controlled Locations (Operational)
ET SI ET S 300-386 EMI/EMC
Power and Grounding
ET S 300 132-1 Equipment Requirements for AC Power Equipment Derived
from DC Sources
ET S 300 132-2 Equipment Requirements for DC
Powered Equipment
ET S 300 253 Facility Requirements
Physical Design and Mounting
Tabletop
Rack Mount 19-inch rack mount supporting racks compliant with:
• ANSI/EIA -310-D
• ET S 300 119
• GR-63-CORE Seismic Zone 4
Environmental Regulatory Compliance
• EU 2002/95/EC RoHS (with lead exemption)
• EU 2002/96/EC WEEE
Network Equipment Building Standards (NEBS)
• GR-1089-CORE NEBS EMC and Safety
• GR-63 CORE: NEBS Physical Protection
• SR-3580: NEBS Criteria Levels (Level 3)