Replacing a power supply
DRAFT: BROCADE CONFIDENTIAL
You are asked to verify this command by entering y for “yes” or n for “no.
Syntax: power-supply monitoring clear <decimal | all>]
By default, no power-supply monitoring is configured.
The decimal variable specifies a power supply number, The all keyword clears all available power supplies.
Displaying power supply monitoring timestamps
To display timestamps for failures on any power supply, enter the following command.
Brocade #show power-supply-monitoring
PS-1 PS-2 PS-3 PS-4
1 ) 0 0 0 0
2 ) 0 0 0 0
3 ) 0 0 0 0
4 ) 0 0 0 0
5 ) 0 0 0 0
6 ) 0 0 0 0
7 ) 0 0 0 0
8 ) 0 0 0 0
9 ) 0 0 0 0
10) 0 0 0 0
11) 0 0 0 0
12) 0 0 0 0
13) 0 0 0 0
14) 0 0 0 0
15) 0 0 0 0
16) 0 0 0 0
17) 0 0 0 0
18) 0 0 0 0
19) 0 0 0 0
20) 0 0 0 0
21) 0 0 0 0
22) 0 0 0 0
23) 0 0 0 0
24) 0 0 0 0
25) 0 0 0 0
26) 0 0 0 0
27) 0 0 0 0
28) 0 0 0 0
29) 0 0 0 0
30) 0 0 0 0
31) 0 0 0 0
32) 0 0 0 0
Monitoring Threshold: 32 flaps/hour
In the example above, the configured power supply monitoring threshold is 32 cycles per hour.
You can also use the show running-config command to display the power supply monitoring threshold configuration, as displayed in the
following example.
Brocade#show running-config
Current configuration:
!
ver V5.4.0T163
module 1 br-mlx-2-port-100g-x