Installation Guide

186 Brocade MLX Series and Brocade NetIron XMR Installation Guide
53-1004195-02
Verifying proper operation
1800W power supplies require 200V-240V for full power or are limited to 1200W with 115V/120V outlets.
2400W and 3000W power supplies require high line (200V-240V) outlets.
If the installation requires a different power cord than the one supplied with the router, make sure you
use a power cord displaying the mark of the safety agency that defines the regulations for power cords in
your country. The mark is your assurance that the power cord can be used safely with the router.
NOTE
Because the router is designed to provide uninterrupted service even when you insert or remove management modules and
interface modules, there is no on/off power switch. To turn the system off, simply unplug the power cords.
NOTE
Wall outlets should be installed near the equipment and easily accessible.
4. Verify that the router has initialized successfully. Refer to “Verifying proper operation” on page 186.
Verifying proper operation
To verify that your router is operating properly, observe the LEDs, or display the status of the modules using the CLI.
Observing the LEDs
When power is supplied to the router, you can observe the LEDs to verify that the router initialized successfully. Table 28 describes the
LEDs, the desired state of each LED, possible abnormal states of each LED, and what to do if an LED indicates an abnormal state.
TABLE 28 Router LED states and actions
LED label Desired state Meaning Abnormal
state
Meaning or action
Management module
Active The Active LED on
one of the installed
management
modules should be
on.
The module is
functioning as the
active management
module.
Off Neither of the management modules is managing the switch
fabric and interface modules. A problem may have occurred
during initialization. Check your attached PC or terminal for
possible error messages.
Pwr On The module is
receiving power.
Off The module is not receiving power. Check the following:
Make certain that the module is installed properly. For more
information, refer to the module installation section in this
chapter that applies to your router model.
If you are using AC power supplies, refer to the AC power
supply LED information in this table for more information.
10/100/1000
Ethernet Port
On (green) A link is established
with the remote
port.
Off A link is not established with the remote port. Check the following:
Verify that the connection to the other router has been
properly made. Also, make certain that the other router is
powered on and operating correctly.
Try using a different cable.