FIPS Security Seal Procedures for Brocade MLXe Series Brocade NetIron CES 2000 Series and Brocade NetIron CER 2000 Series
FIPS Security Seal 13 of 18
Publication Number: 53
-
1002118
-
01
Applying seals to a Brocade MLXe-32 device
Use the figures in this section as a guide for security seal placement on a Brocade MLXe-32 device. Each
Brocade MLXe-32 device requires the placement of 58 seals:
• Front: Affix a total of 48 seals to the front of the chassis. Affix 46 seals—two rows of 11 seals and two rows
of 12—one from each module to the front panel of the chassis. All seals are oriented vertically, and each
seal connects one module to the front panel of the chassis. Affix two seals to the front panel of the
chassis, one covering the right screw and one covering the left screw that secure the front panel to the
chassis. See FIGURE 7 for correct seal orientation and positioning.
• Rear: Affix a total of ten seals to the rear of the device. Affix eight horizontally-oriented seals from the outer
bottom corner of each power supply to the side of the chassis. You must bend these seals to place them
correctly. Affix two seals covering the fans at the base of the rear side of the device. See FIGURE 8 for
correct seal orientation and positioning.