FIPS Security Seal Procedures for Brocade MLXe Series Brocade NetIron CES 2000 Series and Brocade NetIron CER 2000 Series

10 of 18 FIPS Security Seal
Publication Number: 53-1002118-01
Applying seals to a Brocade MLXe-16 device
Use the figures in this section as a guide for security seal placement on a Brocade MLXe-16 device. Each
Brocade MLXe-16 device requires the placement of 24 seals:
Front: A total of 22 seals must be placed on the front panel of each Brocade MLXe-16 device. See FIGURE
5 for correct seal orientation and positioning.
- Affix 11 vertically-oriented seals along the top row of modules; each seal must be affixed to the front
panel of the chassis and to the upper right side of each module.
- Affix 11 vertically-oriented seals along the bottom row of modules; each seal must be affixed to the
bottom left side of each module and to the front panel of the chassis.
Rear: Affix two vertically-oriented seals from the top panel of the chassis covering a portion of the fan unit
lip. One seal will be to the left of the upper leftmost securing post; and the other seal will be to the right of
the rightmost securing post. You must bend these seals to position them correctly. See FIGURE 6 for
correct seal orientation and positioning.