The following table describes how to use the show alarm command to display alarm information.
TABLE 47 Displaying alarm log information
Description Syntax
To display the default alarm levels.
show alarm
default
To display all current alarms of a specic severity:critical, major, or minor.
Alarms displayed depend on what you have congured the alarm logs to record.
show alarm
severity [ critical | major |
minor ]
Use to display all alarms in the alarm logs. Use the history operand to display the alarm history log.
show alarm
[history] all
To display all alarms in the alarm log for all devices in the chassis. Alarms displayed depend on what
you have congured the alarm logs to record.
show alarm
[history] chassis all
To display all alarms in the alarm log related to all subsystems within the chassis or events for a
particular subsystem(where subsystem is power supply or fan)(where x is the device number)
show alarm
[history] chassis subsystem
all | x
To display all alarms in the alarm log for all management modules and subsystems for the
management modules.
show alarm
[history] mp all
To display all alarms in the alarm log related to a specic management module (where n, module
number is 1-3 for MLX/XMR and 1 for CER/CES) and all alarms for it’s subsystems.
show alarm
[history] mp n all
To display all alarms in the alarm log related to temperature information for a management module
(where n, module number is 1-3 for MLX/XMR and 1 for CER/CES)and a specic fan (where x, is
the temperature device number).
show alarm
[history] mp n temperature
[all | x]
To display all alarms in the alarm log for all interface modules and subsystems for the management
module.
show alarm
[history] lp all
To display all alarms in the alarm log related to a specic interface module(where n, module number
is 1-3 for MLX/XMR and 1 for CER/CES) and all alarms for it’s subsystems.
show alarm
[history] lp n all
To display all alarms in the alarm log related to subsystem information for an interface module
(where n, module number is 1-3 for MLX/XMR and 1 for CER/CES)
and either all events on a specic subsystem, or events for a particular subsystem(where subsystem
is temperature or optic)(where x, is a the device number).
show alarm
[history] lp n subsystem [all
| x]
To display all alarms in the alarm log for all SFM and subsystems for the SFM.
show alarm
[history] sfm all