Installation Guide
Table Of Contents
- Extreme Routing MLX Series Hardware Installation Guide
- Preface
- About This Document
- Product Overview
- ExtremeRouting MLX Series device overview
- MLX Series router applications
- Hardware features
- MLX Series router modules
- Management modules
- Interface modules
- 2x100GbE CFP2 optics based high density module
- PBIF Recovery
- 2x100GbE CFP2 P2010 specifications
- 2x100GbE CFP2 DDR3 SDRAM memory specifications
- BR-MLX-10GX20-X2 and BR-MLX-100GX2-CFP2-X2 Router Software
- BR-MLX-10GX20-X2 and BR-MLX-100GX2-CFP2-X2 scalability for IPv4 and IPv6 routes
- MLX Series 2x100G XPP ILKN monitoring
- MLX Series CPU threshold monitoring
- MLX Series BR-MLX-10Gx4-M IPsec and IKEv2
- MLX Series Encryption and Decryption of IPv4 Unicast Data and Control Packets
- MLX Series IKEv2 Authentication
- MLX Series IPsec and IKEv2 configuration
- MLX Series Configuring Global IKEv2 Options
- MLX Series Configuring the IKEv2 Proposal
- MLX Series Configuring the IKEv2 Policy
- MLX Series Configuring the IKEv2 Profile
- MLX Series Configuring the IKEv2 authentication proposal
- MLX Series Configuring the IPsec Proposal
- MLX Series Configuring the IPsec Profile
- MLX Series IKEv2 Show Commands
- MLX Series IKEv2 Clear Commands
- MLX-10GX4-IPSEC-M Forwarding
- MLX Series 2x100G XPP ILKN monitoring
- 10Gx24-port interface module
- MLX 24-port 10Gbps (BR-MLX-10Gx24-DM) Interface Modules
- 8x10GE-X interface modules
- Gen-1 10Gx2 and 10Gx4 Ethernet interface modules
- BR-MLX-10GX4-X and BR-MLX-10Gx4-X-ML interface module LEDs
- Gen-1.1 4-port 10 Gbps Ethernet interface modules
- 8-port 10 Gbps M and D interface modules
- 24-port 1 Gbps Ethernet copper RJ-45 interface module
- 24-port 1 Gbps fiber interface module
- 20-port 100/1000 Ethernet interface module
- 20-port 10/100/1000 Ethernet interface module
- NI-MLX-1Gx48-T-A interface module
- BR-MLX-40Gx4-M 4-port 40GbE module
- Auto-tuning links
- Forward Error Correction mode
- Switch fabric modules
- High-speed switch fabric modules
- CFP2 to QSFP28 conversion module
- Power supplies
- Rack mounting brackets
- Cooling system for MLX Series routers
- NIBI-16-FAN-EXH-A high-speed fan assemblies
- Rack mount kit
- Supported software features
- Installing an ExtremeRouting MLX Series device
- Pre-Installation notice for the ExtremeRouting MLX chassis bundles
- Installation precautions
- Installing 2x100GbE CFP2 interface modules
- Installing BR-MLX-10Gx24-DM interface modules
- Installing an MLXe-4 router
- Installing an MLX-8 router
- Installing an MLXe-16 router
- Mounting the MLX-4, MLX-8 or MLX-16 router in a 4-post rack or EIA rack
- Installing an MLXe-32 router
- Preparing the installation site
- MLXe-32 router shipping carton contents
- Unpacking your MLXe-32 router
- Installing an MLXe-32 router in an EIA rack
- Installing modules in the MLXe-32 router
- MLXe-32 router cable management
- Accessing modules for service
- Installing power supplies in an MLXe-32 router
- Connecting AC power
- Connecting DC power
- Removing the MLXe-32 router DC power supplies
- Final steps
- Attaching a management station
- Activating the power source
- Verifying proper operation
- Using Extreme Structured Cabling Components
- Cable cinch overview
- mRJ21 procedures
- RJ-45 procedures
- Cable cinch with one group of RJ-45 cables
- Cable cinch with two groups of RJ-45 cables
- Cable cinch with three groups of RJ-45 cables
- Cable cinch with four groups of RJ-45 cables
- Cable cinch with five groups of RJ-45 cables
- Cable cinch with six groups of RJ-45 cables
- Cable cinch with seven groups of RJ-45 cables
- Cable cinch with eight groups of RJ-45 cables
- Connecting a Router to a Network Device
- Managing Routers and Modules
- Managing the device
- Disabling and re-enabling power to interface modules
- Monitoring I2C failures on management modules
- Displaying device status and temperature readings
- Displaying the Syslog configuration and static and dynamic buffers
- Router Headless State by MP Presence from LP
- Rolling Reboot
- Line Module Configuration Deletion in Interactive Boot Mode
- Managing switch fabric modules
- Managing the cooling system
- Managing interface modules
- Configuring interface module boot parameters
- Synchronizing the software image between management modules and interface modules
- Changing the boot source
- Specifying an immediate boot
- Specifying an immediate boot from the auxiliary flash slots on the management module
- Specifying an immediate boot from management module flash memory
- Specifying an immediate boot from flash memory on the interface module
- Specifying an immediate boot from a TFTP server
- Specifying an immediate interactive boot
- Configuring an automatic boot
- Configuring an automatic boot from the auxiliary flash slot on the management module
- Configuring an automatic boot from flash memory on the management module
- Configuring an automatic boot from flash memory on the interface module
- Configuring an automatic boot from a TFTP server
- Configuring an automatic interactive boot
- Changing priority of slots for interface modules
- Disabling and re-enabling power to interface modules
- Configuring interface module boot parameters
- Monitoring Link Status
- Traffic Manager XPP link monitoring
- Using alarms to collect and monitor device status
- Displaying MR2 management module memory usage
- Enabling and disabling management module CPU usage calculations
- Displaying management module CPU usage
- Removing MAC address entries
- IPv6 ND Proxy
- DRBG Health Test on IPsec LP
- Managing the device
- Maintenance and Field Replacement
- Maintenance and field replacement overview
- Hardware maintenance schedule
- Replacing a management module
- Replacing an interface module
- Replacing a switch fabric module
- Replacing a fiber-optic transceiver
- Replacing a power supply
- Replacing fan assemblies
- Hardware Specifications
- ExtremeRouting MLX Series Chassis Bundles
- Regulatory Statements
- Caution and Danger Notices
FIGURE 85 Accessing modules by shifting cable bundles
1. Cable bundles
Cable management notes
The following rules apply when setting up cable management for a heavily- or fully-loaded system:
• All cables must be
rmly connected, supported, and contained.
• Use cable cinches, spaced approximately every 24 inches, to secure all of the cables for each module into a single bundle. This
is especially important at the ends nearest the module connections. Each cable cinch holds up to 8 MRJ21 cables, or 48
RJ-45 cables.
• For additional security, use cable ties to secure cables to the cable management system hardware on the sides of the unit.
• The cable routing slots at the top and bottom of the unit are strong enough to hold many cables, but the more cable cinches
and cable ties you use, the more secure your cable management system will be.
• If you bundle the cables correctly, you will be able to move the bundles to the side to access the modules for service, without
disturbing the connections. Refer to Accessing modules for service on page 165.
• Always route the cables for the outer-most modules out the sides of the unit. Route the cables for the innermost modules
through the top or through the bottom cable management hardware on the unit.
Installing power supplies in an MLXe-32 router
DANGER
High Touch Current. Earth connection essential before connecting supply.
Follow these steps to install a power supply in an MLXe-32 router.
1. Remove the blank power supply faceplate.
Installing an MLXe-32 router
Extreme Routing MLX Series Hardware Installation Guide
166 9035627-01