Technical Specs
Table Of Contents
- ExtremeRouting MLX Series Technical Specifications
- ExtremeRouting MLX Series Technical Specifications
- System specifications
- Ethernet
- LEDs
- Other
- Weight and physical dimensions
- Environmental requirements
- Power supply specifications (per PSU)
- Power consumption (maximum configuration)
- Power consumption (modules)
- Data port specifications (Ethernet)
- Serial port specifications (DB9)
- Serial port specifications (pinout RJ-45)
- Serial port specifications (protocol)
- Memory specifications
- Regulatory compliance (EMC)
- Regulatory compliance (safety)
- Regulatory compliance (environmental)
- ExtremeRouting MLX Series Technical Specifications
Model Height Width Depth Weight (empty) Weight (fully loaded)
24.5 inches 17.5 inches 24.2 inches 100 lb 351 lb
MLXe-32 146.7 cm
57.8 inches
44.3 cm
17.5 inches
68.5 cm
27.0 inches
129 kg
284 lb
229 kg
505 lb
Environmental requirements
Condition Operational Non-operational
Ambient temperature 0°C to 40°C (32°F to 104°F) -25°C to 70°C (-13°F to 158°F)
Relative humidity (non-
condensing)
5% to 95% at 40°C (104°F) 95% maximum
Altitude (above sea level) 2012 m (6600 feet) 4500 m (15,000 feet)
Shock N/A N/A
Vibration N/A N/A
Airow N/A N/A
Heat dissipation N/A N/A
Operating noise N/A N/A
Power supply specications (per PSU)
NOTE
3000W power supplies do not support low line AC input voltage.
NOTE
1200W and 2400W power supplies are no longer available for purchase.
Power supply
model
Maximum output
power rating (DC)
Input voltage Input line
frequency
Maximum input
current
Input line
protection
Maximum inrush
current
MLXe-4, MLXe-8, and MLXe-16 routers
N/A 1200 W 100 - 240 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz (range)
16 A Line & Neutral
Fused
<60 A peak for
<10 ms at cold or
warm start
<25 A peak for
cycles 10 ms -
150 ms
BR-MLXE-
ACPWR-1800
1200 W 100-180 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz (range)
16 A Line & Neutral
Fused
<60 A peak for
<10 ms at cold or
warm start
<25 A peak for
cycles 10 ms -
150 ms
1800 W 180-240 VAC
(nominal)
90 - 264 VAC
(range)
50/60 Hz
(nominal)
47 - 63 Hz (range)
16 A Line & Neutral
Fused
<60 A peak for
<10 ms at cold or
warm start
Power supply specications (per PSU)
ExtremeRouting MLX Series Technical Specications
9035593-01 7