Installation Guide

Table Of Contents
TABLE 7 Management module LEDs
LED Position State Meaning
Port 1 and Port 2 Each adjacent to the auxiliary ash
slot that it represents
On or blinking The software is currently accessing
the auxiliary ash card.
O The software is not currently
accessing an auxiliary ash card,
although there is one inserted in the
slot.
Active Lower Left On The module is functioning as the
active management module.
O The module is functioning as the
redundant management module.
Pwr Upper Left On The module is receiving power.
O The module is not receiving power.
10/100/1000 Ethernet Port Above and right of RJ-45
connector
On (Green) A link is established with the remote
port.
O No link is established with the
remote port.
10/100/1000 Ethernet Port Above and left of RJ-45 connector On or blinking (Yellow) The port is transmitting and
receiving packets.
O for an extended period The port is not transmitting or
receiving packets.
Pre-installation notice for MLX Series chassis bundles with MR2 management modules
The following conditions must be met for any chassis with a MR2 management module to operate properly.
The MR2 module requires a minimum Extreme NetIron software version R05.2.00b to operate. Do not attempt to downgrade
the MR2 module to a release lower than R05.2.00b.
MR2-M and MR2-X modules cannot be mixed together in any MLX Series chassis
MR and MR2 modules cannot be mixed together in any MLX Series chassis
Do not downgrade the MBRIDGE version on the MR2 module.
The MR2 management module requires MBRIDGE version 36 or later for 4-, 8-, and 16-slot devices
The MR2 management module requires MBRIDGE32 version 35 or later for 32-slot devices
In certain module combinations, you will need to make sure the supported software is loaded.
Interface modules
Three generations of interface modules exist for MLX Series routers.
The following table lists interface modules that are available for MLX Series routers.
TABLE 8 Interface modules for all MLX Series routers
SKU Ports Description Generation
BR-MLX-100GX2-CFP2-M 2 MLXe two (2)-port 100-GbE (M) module with
IPv4/IPv6/MPLS hardware support. Requires
CFP2 optics. Supports 512K IPv4 routes in FIB.
Requires high speed switch fabric modules.
Gen 3
BR-MLX-100GX2-CFP2-X2 2 MLXe two (2)-port 100-GbE (X2) module with
IPv4/IPv6/MPLS hardware support. Requires
Gen 3
MLX Series router modules
Extreme Routing MLX Series Hardware Installation Guide
32 53-1004203-04