Installation Guide

Table Of Contents
TABLE 6 Management modules for all MLX Series routers (continued)
Part number Description Notes
NI-MLX-32-MR (MR) MLX SeriesMLXe-32 and MLX Series-32
management module, 1 GB SDRAM, dual auxiliary
ash slots, EIA or TIA-232 and 10/100/1000
Ethernet ports for out-of-band management.
This module is no longer supported from
Extreme NetIron R05.7.xx.
NI-XMR-MR (MR) XMR Series management module, 2 GB SDRAM,
dual auxiliary ash slots, EIA or TIA-232 and
10/100/1000 Ethernet ports for out-of-band
management.
This module is no longer supported from
Extreme NetIron R05.7.xx.
NI-XMR-32-MR (MR) XMR Series 32000 management module, 2 GB
SDRAM, dual auxiliary ash slots, EIA or TIA-232 and
10/100/1000 Ethernet ports for out-of-band
management.
This module is no longer supported from
Extreme NetIron R05.7.xx.
BR-MLX-MR2-M (MR2) MLXe/MLX Gen2 management (M) module for
4-, 8- and 16-slot systems. Includes 4 GB RAM, 1
internal compact ash drive (2 GB), 1 external compact
ash slot with included 2 GB card, RS-232 serial
console port and 10/100/1000 Ethernet port for
management.
You must use one of the relevant MR2 modules
starting from Extreme NetIron R05.8.00.
BR-MLX-MR2-X (MR2) MLXe/XMR Gen2 management (X) module for
4-, 8- and 16-slot systems. Includes 4 GB RAM, 1
internal compact ash drive (2 GB), 1 external compact
ash slot with included 2 GB card, RS-232 serial
console port and 10/100/1000 Ethernet port for
management.
You must use one of the relevant MR2 modules
starting from Extreme NetIron R05.8.00.
BR-MLX-32-MR2-M (MR2) MLXe Gen2 management (M) module for 32-
slot systems. Includes 4 GB RAM, 1 internal compact
ash drive (2 GB), 1 external compact ash slot with
included 2 GB card, RS-232 serial console port and
10/100/1000 Ethernet port for management.
You must use one of the relevant MR2 modules
starting from Extreme NetIron R05.8.00.
BR-MLX-32-MR2-X (MR2) MLXe/XMR Gen2 management (X) module for
32-slot systems. Includes 4 GB RAM, 1 internal
compact ash drive (2 GB), 1 external compact ash
slot with included 2 GB card, RS-232 serial console
port and 10/100/1000 Ethernet port for
management.
You must use one of the relevant MR2 modules
starting from Extreme NetIron R05.8.00.
The management module controls the hardware components, runs the networking protocols, and provides the Real Time Operating
System (RTOS).
Each router requires one management module, and can accommodate a second module for redundancy. A redundant management
module works in conjunction with the active management module. If the active module becomes unavailable, the redundant
management module automatically takes over the system operation, minimizing system downtime. For information about the
redundancy feature, refer to the Extreme NetIron Switching Conguration Guide.
Management modules are installed in dedicated slots marked M1 and M2. By default, the module installed in slot M1 is the active
management module.
Management modules are hot-swappable, which means you can remove and replace them without powering down the system.
NOTE
MR and MR2 management modules cannot be mixed in the same chassis.
MLX Series router modules
Extreme Routing MLX Series Hardware Installation Guide
53-1004203-04 29