Installation Guide
Table Of Contents
- Extreme Routing MLX Series Hardware Installation Guide
- Preface
- About This Document
- Product Overview
- ExtremeRouting MLX Series device overview
- MLX Series router applications
- Hardware features
- MLX Series router modules
- Management modules
- Interface modules
- 2x100GbE CFP2 optics based high density module
- PBIF Recovery
- 2x100GbE CFP2 P2010 specifications
- 2x100GbE CFP2 DDR3 SDRAM memory specifications
- BR-MLX-10GX20-X2 and BR-MLX-100GX2-CFP2-X2 Router Software
- BR-MLX-10GX20-X2 and BR-MLX-100GX2-CFP2-X2 scalability for IPv4 and IPv6 routes
- MLX Series 2x100G XPP ILKN monitoring
- MLX Series CPU threshold monitoring
- MLX Series BR-MLX-10Gx4-M IPsec and IKEv2
- MLX Series Encryption and Decryption of IPv4 Unicast Data and Control Packets
- MLX Series IKEv2 Authentication
- MLX Series IPsec and IKEv2 configuration
- MLX Series Configuring Global IKEv2 Options
- MLX Series Configuring the IKEv2 Proposal
- MLX Series Configuring the IKEv2 Policy
- MLX Series Configuring the IKEv2 Profile
- MLX Series Configuring the IKEv2 authentication proposal
- MLX Series Configuring the IPsec Proposal
- MLX Series Configuring the IPsec Profile
- MLX Series IKEv2 Show Commands
- MLX Series IKEv2 Clear Commands
- MLX-10GX4-IPSEC-M Forwarding
- MLX Series 2x100G XPP ILKN monitoring
- 10Gx24-port interface module
- MLX 24-port 10Gbps (BR-MLX-10Gx24-DM) Interface Modules
- 8x10GE-X interface modules
- Gen-1 10Gx2 and 10Gx4 Ethernet interface modules
- BR-MLX-10GX4-X and BR-MLX-10Gx4-X-ML interface module LEDs
- Gen-1.1 4-port 10 Gbps Ethernet interface modules
- 8-port 10 Gbps M and D interface modules
- 24-port 1 Gbps Ethernet copper RJ-45 interface module
- 24-port 1 Gbps fiber interface module
- 20-port 100/1000 Ethernet interface module
- 20-port 10/100/1000 Ethernet interface module
- NI-MLX-1Gx48-T-A interface module
- BR-MLX-40Gx4-M 4-port 40GbE module
- Auto-tuning links
- Forward Error Correction mode
- Switch fabric modules
- High-speed switch fabric modules
- CFP2 to QSFP28 conversion module
- Power supplies
- Rack mounting brackets
- Cooling system for MLX Series routers
- NIBI-16-FAN-EXH-A high-speed fan assemblies
- Rack mount kit
- Supported software features
- Installing an ExtremeRouting MLX Series device
- Pre-Installation notice for the ExtremeRouting MLX chassis bundles
- Installation precautions
- Installing 2x100GbE CFP2 interface modules
- Installing BR-MLX-10Gx24-DM interface modules
- Installing an MLXe-4 router
- Installing an MLX-8 router
- Installing an MLXe-16 router
- Mounting the MLX-4, MLX-8 or MLX-16 router in a 4-post rack or EIA rack
- Installing an MLXe-32 router
- Preparing the installation site
- MLXe-32 router shipping carton contents
- Unpacking your MLXe-32 router
- Installing an MLXe-32 router in an EIA rack
- Installing modules in the MLXe-32 router
- MLXe-32 router cable management
- Accessing modules for service
- Installing power supplies in an MLXe-32 router
- Connecting AC power
- Connecting DC power
- Removing the MLXe-32 router DC power supplies
- Final steps
- Attaching a management station
- Activating the power source
- Verifying proper operation
- Using Extreme Structured Cabling Components
- Cable cinch overview
- mRJ21 procedures
- RJ-45 procedures
- Cable cinch with one group of RJ-45 cables
- Cable cinch with two groups of RJ-45 cables
- Cable cinch with three groups of RJ-45 cables
- Cable cinch with four groups of RJ-45 cables
- Cable cinch with five groups of RJ-45 cables
- Cable cinch with six groups of RJ-45 cables
- Cable cinch with seven groups of RJ-45 cables
- Cable cinch with eight groups of RJ-45 cables
- Connecting a Router to a Network Device
- Managing Routers and Modules
- Managing the device
- Disabling and re-enabling power to interface modules
- Monitoring I2C failures on management modules
- Displaying device status and temperature readings
- Displaying the Syslog configuration and static and dynamic buffers
- Router Headless State by MP Presence from LP
- Rolling Reboot
- Line Module Configuration Deletion in Interactive Boot Mode
- Managing switch fabric modules
- Managing the cooling system
- Managing interface modules
- Configuring interface module boot parameters
- Synchronizing the software image between management modules and interface modules
- Changing the boot source
- Specifying an immediate boot
- Specifying an immediate boot from the auxiliary flash slots on the management module
- Specifying an immediate boot from management module flash memory
- Specifying an immediate boot from flash memory on the interface module
- Specifying an immediate boot from a TFTP server
- Specifying an immediate interactive boot
- Configuring an automatic boot
- Configuring an automatic boot from the auxiliary flash slot on the management module
- Configuring an automatic boot from flash memory on the management module
- Configuring an automatic boot from flash memory on the interface module
- Configuring an automatic boot from a TFTP server
- Configuring an automatic interactive boot
- Changing priority of slots for interface modules
- Disabling and re-enabling power to interface modules
- Configuring interface module boot parameters
- Monitoring Link Status
- Traffic Manager XPP link monitoring
- Using alarms to collect and monitor device status
- Displaying MR2 management module memory usage
- Enabling and disabling management module CPU usage calculations
- Displaying management module CPU usage
- Removing MAC address entries
- IPv6 ND Proxy
- DRBG Health Test on IPsec LP
- Managing the device
- Maintenance and Field Replacement
- Maintenance and field replacement overview
- Hardware maintenance schedule
- Replacing a management module
- Replacing an interface module
- Replacing a switch fabric module
- Replacing a fiber-optic transceiver
- Replacing a power supply
- Replacing fan assemblies
- Hardware Specifications
- ExtremeRouting MLX Series Chassis Bundles
- Regulatory Statements
- Caution and Danger Notices
2. Enter the following command at the Privileged EXEC level prompt, then press Enter . This command erases the factory test
conguration if it is still present.
device# erase startup-config
After you enter this command, you will need to restart the system.
CAUTION
Use the erase startup-cong command only for new systems. If you enter this command on a system you have
already congured, the command erases the conguration. If you accidentally erase the conguration on a
congured system, enter the write memory command to save the running conguration to the startup-cong le.
3. Access the conguration level of the CLI by entering the following command.
device# configure terminal
device(config)#
4. Congure the IP address and subnet mask for Ethernet interface 1/1 by entering the following commands.
device(config)# interface ethernet 1/1
device(config-if-e10000-1/1)# ip address 192.22.3.44 255.255.255.0
Syntax: enable [ password ]
Syntax: congure terminal
Syntax: [no] ip address ip-addrip-mask [ secondary ]
or
Syntax: [no] ip address ip-addr/mask-bits [ secondary ]
Use the secondary parameter if you have already congured an IP address within the same sub-net on the interface.
Enabling and disabling the interfaces
By default, all router interfaces are disabled. To enable an interface, enter the enable command at the appropriate interface
conguration
level of the CLI. For example, to enable the management interface, enter the enable command at the management interface
conguration level of the CLI.
device(config-if-mgmt-1)# enable
You can disable each of these interfaces using the disable command at the appropriate interface conguration level of the CLI. For
example, to disable the management port, enter the disable command at the management interface conguration level of the CLI.
device(config-if-mgmt-1)# disable
Understanding management port functions
The management port performs specic functions and is subject to some limitations, as described.
• Because the management port allows you to congure, monitor, and manage routers only, this port has the same limited
functionality as an IP host port.
• You cannot enable and run routing protocols on the management port.
• You cannot congure routes from the management interface.
• The management port uses static IP routes from the interface routing tables.
Understanding management port functions
Extreme Routing MLX Series Hardware Installation Guide
196 53-1004203-04