Installation Guide

Table Of Contents
6. Repeat step 2 through step 5 to mount each router in the rack, moving from lowest to highest.
Installing Brocade MLXe Series-4 modules
The sequence for installing multiple modules is important to ensure proper fit. The recommended sequence for the Brocade MLXe
Series-4 router is to install right-to-left, beginning with the lowest row and moving up.
For instructions about installing 2x100GbE interface modules, refer to Installing 2x100GbE CFP2 interface modules in Brocade MLXe
Series routers on page 92.
For instructions about installing 2x100GbE interface modules, refer to Installing BR-MLX-10Gx24-DM interface modules in Brocade
MLXe Series routers on page 93.
NOTE
Installation procedures are identical for interface, management and switch fabric modules.
DANGER
The intra-building port or ports of the equipment or subassembly is suitable for connection to intra-building or unexposed
wiring or cabling only. The intra-building port or ports of the equipment or subassembly MUST NOT be metallically connected
to interfaces that connect to the outside plant (OSP) or its wiring. These interfaces are designed for use as intra-building
interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 5) and require isolation from the exposed OSP
cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP
wiring.
NOTE
Brocade MLXe Series modules are dedicated, which means that you must install them in Brocade MLXe Series routers only. If
you install a Brocade MLXe Series module in a non-Brocade MLXe Series router, or install a module intended for a non-
Brocade MLXe Series router in a Brocade MLXe Series router, the router and module will not function properly. Although
management modules are designed to be hot-swappable, you must upgrade the software on all interface modules and
management modules to the appropriate software release before installing them. For more information on the appropriate
software release, refer to the Hardware Installation Notes that shipped with the management module.
For information about how to disable and re-enable power to interface modules, refer to Disabling and re-enabling power to interface
modules on page 220.
Modules must be installed in the correct slot number, as shown in the following list. First the slot number is shown, then the module into
which it must be installed. An identifying label can be seen at the base of each slot.
NOTE
The Brocade MLXe Series-4 router ships with the required switch fabric modules installed.
1. Management modules
2. Active module - M1 (left).Redundant module - M2 (right).
3. Interface modules
4. - 4
5. Switch fabric modules
6. SF1 - SF3
If you are installing a redundant management module, refer to the chapter titled "Using a Redundant Management Module" in the
Brocade NetIron MLX Series
and Brocade NetIron Family Configuration Guide
for information about how the redundant module works,
optional software configurations, and how to manage redundancy.
Installing a Brocade MLXe Router
Brocade NetIron MLXe Series Hardware Installation Guide
98 53-1004203-03