Installation Guide

Table Of Contents
NOTE
Not all features available in NetIron R05.4.00 are supported on the BR-MLX-10Gx24-DM interface module. To verify if a
particular feature is supported with the BR-MLX-10Gx24-DM interface module, refer to the latest version of the
Multi-Service
IronWare Configuration Guide
NOTE
For maximum performance, you must operate your BR-MLX-10Gx24-DM interface module with high speed switch fabric
modules in turbo mode. For information on switch fabric modules, refer to Managing switch fabric modules on page 205.
Installation procedure
When installing modules, wear an ESD wrist strap with a plug for connection to the ESD connector on the router chassis or other suitable
ground.
DANGER
For safety reasons, the ESD wrist strap should contain a 1 megohm series resistor.
1. Upgrade the software on all management modules and interface modules to Multi-Service IronWare R05.4.00 or later. For
specific upgrade instructions, refer to the Multi-Service IronWare Upgrade Guide.
2. Configure the snmp maximum interface index per module to 64 using the snmp-server max-ifindex-per-module 64
command
device (config)# snmp-server max-ifindex-per-module 64
3. For MLXe-32 installations only:
a) If the chassis has a Gen-1 module, enter the following commands.
device# config
device(config)# system-init mlxe32-24x10g-enable max-tm-queue-4
device(config)# system-init fabric-data-mode force-normal
device# write memory
device# reload
b) If the chassis has no Gen-1 module, enter the following commands.
device# config
device(config)# system-init mlxe32-24x10g-enable
device# write memory
device# reload
4. Install the BR-MLX-24x10G-DM module.
5. Verify that the module comes up,
NOTE
For known limitations, please refer to the Release Notes shipped with your module.
Installing a Brocade MLXe Series-4 router
This section describes how to install a Brocade MLXe Series-4 router.
Installing a Brocade MLXe Router
Brocade NetIron MLXe Series Hardware Installation Guide
94 53-1004203-03