FIGURE 20 Switch fabric module front panel
TABLE 25 Switch fabric module LEDs
Pwr Above Active LED On The module is receiving power.
Off The module is not receiving power.
Active Below Pwr LED On(4-, 8-, and 16-slot
routers only)
The switch fabric is on (active) and ready to switch user
packets.
Blinking (32-slot routers
only)
The switch fabric is on (active) and being accessed by the
Management Module CPU. This indicates normal
operation.
NOTE
On devices supporting software version
R05.3.00 and earlier, when you insert an SFM
or during powering on the device, the Active
LED was off for a short duration, up to 15
seconds because the monitoring of the Fabric
module is stopped for this duration. After this
delay, the LED indicated the monitoring status.
In version R05.4.00 and later, the Active LED
reads the switch fabric continuously even
during module insertion or powering on the
device, and thus the Active LED blinks.
Off for extended period The switch fabric is not active and cannot switch user
packets.
High-speed switch fabric modules
NOTE
Gen-1 switch fabric modules and Gen-2 high-speed fabric (HSF) modules are not compatible and will not operate together in
the same device.
HSF modules are supported on Brocade MLXe Series routers, and are interoperable with all existing interface modules.
HSF modules are hot-swappable, which means you can install or replace them while the system is powered up and running.
NOTE
Do not remove or power-off all switch fabric modules on MLXe chassis while the device is up and running. Removing all the
switch fabric modules from the device and then re-inserting them can cause the device to become unstable, resulting in
protocol flaps and thereby traffic impact. A system reload is required to recover.
HSF modules can operate in normal mode or turbo mode but will boot in turbo mode only if all active interface modules are Gen-2 and
Gen-3modules.