Installation Guide

Table Of Contents
Two identical CXPP1x100G packet processors are present to perform 200Gbps packet processing.
SYSLOG and SNMP traps are generated if packet drops result from CRC errors in the Interlaken link / interface between iXPP1 and
iXPP2. The affected ports are shutdown if the Interlaken link / interface was configured through the new CLI configuration command
based on the following factors:
The option to shutdown the affected ports is configured using the new global configuration command.
The option to disable the feature is configured using the new global configuration command.
Syslog and SNMP traps are generated once the packets drop are seen because of Interlaken CRC errors. The syslog/SNMP trap is
generated once every 3 minutes with the following information:
Indicating the number of packet drops and CRC errors in each lane group.
Indicating if ports are not disabled by the port shut down option.
Product Overview
Brocade NetIron MLXe Series Hardware Installation Guide
58 53-1004203-03