Installation Guide

Table Of Contents
512K Flash Memory 2x16MB Code, 4MB Boot
64MB Flash Memory for Application Code
PCI bus interface (PBIF) FPGA for PCIe Interface and STATS
Hot Pluggable
Power Consumption: 360W
XPP FPGA for packet processing
Temperature sensor, strategically located on the PCBA
Power, port, and status LED indicators
Link Status per port
JTAG support
Temperature monitoring I
2
C Management Interface
Real Time Clock
Supports 32 GPIO
Supports 9 temperature sensors
The 2x100GbE CFP2 based high density blade provides the following support:
Extended VLAN statistics, sFlow monitoring, Optical Monitoring, CAM MIB, entity MIB, snAgentCpuUtilTable and system
MIBs.
snAgentConfigModuleTable, snSwIfInfoTable, snAgentBrdTable and brcdEntityOIDMIB.
NP and TM counters and statistics.
LP-Auto Upgrade.
4GB DDR3 SDRAM.
NOTE
Web Management Front Panel is not supported for the 2x100GbE CFP2 card.
NOTE
For NetIron 5.7 release only: 2GB of SDRAM memory is usable out of 4GB.
Traffic Manager (TM) traffic behavior for the 2x100GbE CFP2 card is as follows:
E-Chassis and hSFMs are required with the 2x100GbE CFP2 module.
Each 2x100GbE CFP2 TM can support one full 100Gbps wire speed ports.
For best performance, Turbo mode is recommended; 1024B credit size; and full fabric connectivity.
Performance is in turbo mode:
Line rate with all fabrics installed.
With N-1 fabrics, line rate is in MLXe 32; however, most packet size line rates are in MLXe 16.
NOTE
No line rates are in MLXe 8 and 4.
Performance is in non turbo mode:
No line rate for certain smaller packet sizes (even with all fabrics installed).
NOTE
Dynamic port configuration for the 2x100GbE CFP2 based high density blade chassis is shown in the topic 2x100GbE CFP2
Dynamic Port Configuration on page 269.
Product Overview
Brocade NetIron MLXe Series Hardware Installation Guide
36 53-1004203-03