Router modules
The Brocade MLXe Series routers support a number of management modules, interface modules, and switch fabric modules, as shown
in the following content.
Management modules
Brocade MLXe Series routers support the following management modules types.
MR management module
MR2 management module
The following table lists the management modules available for Brocade MLXe Series routers.
TABLE 6 Management modules for all Brocade MLXe Series routers
Part number Description Notes
NI-MLX-MR (MR) Brocade MLXe Series and Brocade NetIron MLX
Series management module, 1 GB SDRAM, dual
auxiliary flash slots, EIA or TIA-232 and 10/100/1000
Ethernet ports for out-of-band management.
This module is no longer supported from
NetIron R05.7.xx.
NI-MLX-32-MR (MR) Brocade MLXe Series-32 and Brocade NetIron
MLX Series-32 management module, 1 GB SDRAM,
dual auxiliary flash slots, EIA or TIA-232 and
10/100/1000 Ethernet ports for out-of-band
management.
This module is no longer supported from
NetIron R05.7.xx.
NI-XMR-MR (MR) Brocade NetIron XMR Series management
module, 2 GB SDRAM, dual auxiliary flash slots, EIA or
TIA-232 and 10/100/1000 Ethernet ports for out-of-
band management.
This module is no longer supported from
NetIron R05.7.xx.
NI-XMR-32-MR (MR) Brocade NetIron XMR Series 32000
management module, 2 GB SDRAM, dual auxiliary
flash slots, EIA or TIA-232 and 10/100/1000 Ethernet
ports for out-of-band management.
This module is no longer supported from
NetIron R05.7.xx.
BR-MLX-MR2-M (MR2) MLXe/MLX Gen2 management (M) module for
4-, 8- and 16-slot systems. Includes 4 GB RAM, 1
internal compact flash drive (2 GB), 1 external compact
You must use one of the relevant MR2 modules
starting from NetIron R05.8.00.
Product Overview
Brocade NetIron MLXe Series Hardware Installation Guide
28 53-1004203-03