Installation Guide
Table Of Contents
- Brocade NetIron MLXe Series Hardware Installation Guide
- Preface
- About This Document
- Product Overview
- Brocade router overview
- Router applications
- Hardware features
- Router modules
- Management modules
- Interface modules
- 2x100GbE CFP2 optics based high density module
- PBIF Recovery
- 2x100GbE CFP2 P2010 specifications
- 2x100GbE CFP2 DDR3 SDRAM memory specifications
- BR-MLX-10GX20-X2 and BR-MLX-100GX2-CFP2-X2 Router Software
- BR-MLX-10GX20-X2 and BR-MLX-100GX2-CFP2-X2 scalability for IPv4 and IPv6 routes
- 2x100G XPP ILKN monitoring
- CPU threshold monitoring
- MLXe BR-MLX-10Gx4-M IPsec and IKEv2
- Encryption and Decryption of IPv4 Unicast Data and Control Packets
- IKEv2 Authentication
- IPsec and IKEv2 configuration
- Configuring Global IKEv2 Options
- Configuring the IKEv2 Proposal
- Configuring the IKEv2 Policy
- Configuring the IKEv2 Profile
- Configuring the IKEv2 authentication proposal
- Configuring the IPsec Proposal
- Configuring the IPsec Profile
- IKEv2 Show Commands
- IKEv2 Clear Commands
- MLX-10GX4-IPSEC-M Forwarding
- 2x100G XPP ILKN monitoring
- 10Gx24-port interface module
- MLX 24-port 10Gbps (BR-MLX-10Gx24-DM) Interface Modules
- 8x10GE-X interface modules
- Gen-1 10Gx2 and 10Gx4 Ethernet interface modules
- BR-MLX-10GX4-X and BR-MLX-10Gx4-X-ML interface module LEDs
- Gen-1.1 4-port 10 Gbps Ethernet interface modules
- 8-port 10 Gbps M and D interface modules
- 24-port 1 Gbps Ethernet copper RJ-45 interface module
- 24-port 1 Gbps fiber interface module
- 20-port 100/1000 Ethernet interface module
- 20-port 10/100/1000 Ethernet interface module
- NI-MLX-1Gx48-T-A interface module
- BR-MLX-40Gx4-M 4-port 40GbE module
- Auto-tuning links
- Forward Error Correction mode
- Switch fabric modules
- High-speed switch fabric modules
- CFP2 to QSFP28 conversion module
- Power supplies
- Rack mounting brackets
- Cooling system for Brocade MLXe Series routers
- NIBI-16-FAN-EXH-A high-speed fan assemblies
- Rack mount kit
- Supported software features
- Installing a Brocade MLXe Router
- Pre-Installation notice for the Brocade MLXe chassis bundles
- Installation precautions
- Installing 2x100GbE CFP2 interface modules in Brocade MLXe Series routers
- Installing BR-MLX-10Gx24-DM interface modules in Brocade MLXe Series routers
- Installing a Brocade MLXe Series-4 router
- Installing a Brocade MLXe Series-8 router
- Installing a Brocade MLXe Series-16 router
- Mounting Brocade MLXe Series-4, -8, or -16 routers in a 4-post EIA rack
- Installing a Brocade MLXe Series-32 router
- Preparing the installation site
- Brocade MLXe Series-32 router shipping carton contents
- Unpacking your Brocade MLXe Series-32 router
- Installing a Brocade MLXe Series-32 router in an EIA rack
- Installing modules in the Brocade MLXe Series-32 router
- Brocade MLXe Series-32 cable management
- Accessing modules for service
- Installing power supplies in a Brocade MLXe Series-32 router
- Connecting AC power
- Connecting DC power
- Removing Brocade MLXe Series-32 router DC power supplies
- Final steps
- Attaching a management station
- Activating the power source
- Verifying proper operation
- Using Brocade Structured Cabling Components
- Cable cinch overview
- mRJ21 procedures
- RJ-45 procedures
- Cable cinch with one group of RJ-45 cables
- Cable cinch with two groups of RJ-45 cables
- Cable cinch with three groups of RJ-45 cables
- Cable cinch with four groups of RJ-45 cables
- Cable cinch with five groups of RJ-45 cables
- Cable cinch with six groups of RJ-45 cables
- Cable cinch with seven groups of RJ-45 cables
- Cable cinch with eight groups of RJ-45 cables
- Connecting a Router to a Network Device
- Managing Routers and Modules
- Managing the device
- Disabling and re-enabling power to interface modules
- Monitoring I2C failures on management modules
- Displaying device status and temperature readings
- Displaying the Syslog configuration and static and dynamic buffers
- Router Headless State by MP Presence from LP
- Rolling Reboot
- Line Module Configuration Deletion in Interactive Boot Mode
- Managing switch fabric modules
- Managing the cooling system
- Managing interface modules
- Configuring interface module boot parameters
- Synchronizing the software image between management modules and interface modules
- Changing the boot source
- Specifying an immediate boot
- Specifying an immediate boot from the auxiliary flash slots on the management module
- Specifying an immediate boot from management module flash memory
- Specifying an immediate boot from flash memory on the interface module
- Specifying an immediate boot from a TFTP server
- Specifying an immediate interactive boot
- Configuring an automatic boot
- Configuring an automatic boot from the auxiliary flash slot on the management module
- Configuring an automatic boot from flash memory on the management module
- Configuring an automatic boot from flash memory on the interface module
- Configuring an automatic boot from a TFTP server
- Configuring an automatic interactive boot
- Changing priority of slots for interface modules
- Disabling and re-enabling power to interface modules
- Configuring interface module boot parameters
- Monitoring Link Status
- Traffic Manager XPP link monitoring
- Using alarms to collect and monitor device status
- Displaying MR2 management module memory usage
- Enabling and disabling management module CPU usage calculations
- Displaying management module CPU usage
- Removing MAC address entries
- IPv6 ND Proxy
- DRBG Health Test on IPsec LP
- Managing the device
- Maintenance and Field Replacement
- Maintenance and field replacement overview
- Hardware maintenance schedule
- Replacing a management module
- Replacing an interface module
- Replacing a switch fabric module
- Replacing a fiber-optic transceiver
- Replacing a power supply
- Replacing fan assemblies
- Hardware Specifications
- Brocade MLXe Chassis Bundles
- Regulatory Statements
- Caution and Danger Notices
TABLE 43 Temperature threshold information for modules and fan speeds (continued)
This field... Displays...
NOTE
As indicated in Table 44, the low fan speed for each module
does not have a default low temperature threshold value, nor
can you configure this value. The "-1" value that appears in the
Fan Speed Low field for each module is a Brocade internal
value only.
State = 0 (FAN_STATE_LOW) For Brocade internal use only.
max_ts_shut_off_count For Brocade internal use only.
shut_off_count = 0 0 0 0 0 0 0 0 For Brocade internal use only.
When syslog messages display a change in fan speed, you can identify which sensors triggered the change by checking show chassis
and show fan-threshold command output and looking for sensors with temperatures near threshold boundaries. The following table lists
the associations between the show chassis , show fan-threshold , and fan-threshold commands .
NOTE
A "thermal block" refers to the group of high and low thresholds for all fan speed levels.
TABLE 44 Associations between show chassis, show fan threshold, and fan-threshold commands
show chassis command output (sensors) show fan-threshold command output (thermal
block)
fan-threshold command configuration
MP, SFM, and hSFM Modules
Active Management 1st reading THERMAL_SENSOR_TEST_RULE_MP fan-threshold mp
Active Management 2nd reading THERMAL_SENSOR_TEST_RULE_MP_CPU fan-threshold mp-cpu
Standby Management 1st reading THERMAL_SENSOR_TEST_RULE_STANDBY
_MP
fan-threshold mp
Standby Management 2nd reading THERMAL_SENSOR_TEST_RULE_STANDBY
_MP_CPU
fan-threshold mp-cpu
SFM FE1 reading THERMAL_SENSOR_TEST_RULE_SNM fan-threshold switch-fabric
SFM FE2 reading THERMAL_SENSOR_TEST_RULE_SNM fan-threshold switch-fabric
SFM FE3 reading THERMAL_SENSOR_TEST_RULE_SNM fan-threshold switch-fabric
hSFM FE1 reading THERMAL_SENSOR_TEST_RULE_SNM_G2 fan-threshold switch-fabric-g2
hSFM FE2 reading THERMAL_SENSOR_TEST_RULE_SNM_G2 fan-threshold switch-fabric-g2
hSFM FE3 reading THERMAL_SENSOR_TEST_RULE_SNM_G2 fan-threshold switch-fabric-g2
LP Modules (1 or 2 Traffic Managers)
LP Sensor 1 reading (TM 0) THERMAL_SENSOR_TEST_RULE_LP fan-threshold lp
LP Sensor 2 reading (TM 0) THERMAL_SENSOR_TEST_RULE_LP_XPP N/A (Must not be changed)
LP Sensor 3 reading (TM 1) THERMAL_SENSOR_TEST_RULE_LP fan-threshold lp
LP Sensor 4 reading (TM 1) THERMAL_SENSOR_TEST_RULE_LP_XPP N/A (Must not be changed)
NI-MLX-10Gx8-M LP Modules
LP2 Sensor 1 reading THERMAL_SENSOR_TEST_RULE_LP_2 fan-threshold lp2
LP2 Sensor 2 reading THERMAL_SENSOR_TEST_RULE_LP_XPP2 N/A (Must not be changed)
LP2 Sensor 3 reading UNUSED UNUSED
LP2 Sensor 4 reading THERMAL_SENSOR_TEST_RULE_LP_2 fan-threshold lp2
LP2 Sensor 5 reading THERMAL_SENSOR_TEST_RULE_LP_XPP2 N/A (Must not be changed)
Managing Routers and Modules
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-03 211