Installation Guide

Table Of Contents
SummitStack-V400
Table 94: Matrix of Switches and Stacking Methods
Stack with X440-
G2
1
X450-
G2
2
X460-
G2
1
X590
3
X465 X620 X670-
G2
4
X690 X695 X870
X440-G2
1
V V V V V
X450-G2
2
V V
V84
V V V
X460-G2
1
V V 40G
SS
V
V160
V V
V160
X590
3
V400 V160 V400 V400 V400
X465 V160 V160 V160
X620 V V V V V
X670-G2
4
V V V
V160
V V
V80
(suppor
ted in
EXOS
30.1 and
prior
releases
)
V160
V320
X690 V400 V160 V400 V400 V400
X695 V400 V160 V400 V400 V400
X870 V400 V400 V400 V400
Note
1. For X440-G2 and X460-G2, SummitStack-V is available only on 10G models.
2. For X450-G2, SummitStack-V is available only on 10G models. SummitStack-V84 is
available only in stacks that consist entirely of X450-G2 switches.
3. The X590 is not supported with ExtremeXOS version 30.1.
4. The X670-G2-72x can stack only with SummitStack V using front panel 10G ports.
In a stack that has switch models from more than one series, we recommend that the stack master and
backup nodes be from the same switch series. For example, if an X460-G2 switch is the stack master,
the backup node should also be an X460-G2 switch. Refer to the list in Master/Backup Switch
Redundancy on page 182.
Stack configuration, easy setup, and redundancy are fully described in the ExtremeXOS 30.7 User Guide.
Building Stacks
Combining Switches from Dierent Series
ExtremeSwitching Hardware Installation Guide 209