User guide
Summit GbX Installation and User Guide 19
Technical Specifications
4 Reconnect the SummitGbX LDI ports to the optical plant. Using the management
interface of the remote SummitGbX, enable LDI Loopback. Verify Loopback Enabled
status. The LDI Loop Back LED should be yellow.
5 Using the management interface of the remote SummitGbX, disable LDI Loopback.
Verify Loopback Disabled status. The LDI Loop Back LED should be green. Connect
the remote SummitGbX GBE TX output to the same SummitGbX RX input using
multimode fiber.
6 Using multimode fiber jumper(s), connect the remote Host’s GBE TX and RX ports.
SummitGbX inputs and outputs are susceptible to damage through electro-static
discharge (ESD). Always use ESD control measures when operating the unit.
T
ECHNICAL
S
PECIFICATIONS
The following tables list the technical specifications for the SummitGbX.
Physical Dimensions
Height: 1.75 inches (4.45 cm) x Width: 19 inches (48.26
cm) x Depth: 15 inches (38.14 cm)
Weight: 7.5 lbs. (2.5 kg)
Environmental Requirements
Operating temperature 0° C to 50° C
Storage temperature -10° C to 70° C
Operating humidity 10% to 95% relative humidity, noncondensing
Standards EN60068 (IEC68)
Safety
Agency certifications cUL listed to CSA C22.2 #950; 95
Electromagnetic Compatibility
FCC part 15 Class A
CE Mark
Power Supply
AC line frequency 50/60Hz
Input voltage options 100VAC to 240VAC auto-switching
Power rating 50 watts