Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.2 Release Notes
86
PD4-855250053,
PD4-843000831
The counter for the show traffic queue statistics command is displayed as
"multiple" when ingress ports are on different I/O modules but all ports have the same
egress ports.
PD4-953613971,
PD4-944885511
Receiving LACP PDUs that are larger than 500 causes the LACP process to die with a
signal 11 error.
PD4-962772378,
PD4-924242747
The FDB process may die with signal 11 when the show fdb statistics command
is executed.
PD4-974227479,
PD4-767595507
The log filter is not shown in the output of the show upm profile <profile-name>
command.
PD4-843337987,
PD4-748079627
The debug log <Info:thttpd.info> 13 line feeds removed is not necessary
and is shown when configuring a switch with HTTPS.
PD4-985272501,
PD4-943063565
The cliMaster fails with a signal 6 error when running the show configuration pim
command while PIM is configured with a static CRP.
PD4-980404139,
PD4-899333484
The thttpd process CPU utilization increases and HTTP/HTTPS is not accessible if sock/
stress attack is performed on an HTTPS port. This issue persists indefinitely even after a
sock/stress attack is removed.
PD4-985606480,
PD4-791833227
If an IPv6 tunnel is configured, adding a static route causes the Route Table Manager to
crash with a signal 11 error.
PD4-826754349,
PD4-581257425
An error occurs when loading an ExtremeXOS 12.1 or earlier software configuration file if
the banner configuration contains a new line character.
PD4-806088040,
PD4-684400473
A switch does not generate high CPU utilization log messages after executing the clear
cpu-utilization command, even if process CPU utilization goes above the threshold value.
PD4-993453673,
PD4-983772991
The ifMauDefaultType MIB is populated with the wrong value when a switch is running
ExtremeXOS 12.3.3 software.
PD4-1023187137,
PD4-968719352
When running the terminate process exsshd forceful command while an SSH
session is in progress, the SSH session does not shut down even if it is no longer seen in
the output of the show session command. When restarting the SSH session using the
start process exsshd command, the switch appears to hang while waiting for the
ongoing SSH session to be terminated.
PD4-1005347431,
PD4-990080561
In CLI non-persistent mode, modifying a port in a VLAN from an untagged port to a
tagged port deletes the port from that VLAN.
BlackDiamond 8800 Series Switch
PD3-190363671 The following error message is displayed while hot swapping PSUs:
Unable to read PSU-2 FRU data. Try reinserting PSU more quickly.
Workaround: Remove and reinsert the PSU quickly. Insert the PSU in a single, continuous
motion with a firm push.
PD4-910971021
Port Summary Monitor timestamps display on a console as part of the show port
<port _list> command output.
PD4-983675112,
PD4-983613057
The conversion of RX and TX power from uW (as read from the optic) to dBm incorrectly
uses the natural log function rather than the log base 10 function. The status of RX and
TX power is correct, but the values shown are not correct.
Table 44: Platform-Specific and Feature PDs (Continued)
PD Number Description