Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.2 Release Notes
85
PD4-734160746 In a private VLAN spanning two switches, when one of the switches has loopback-port
configured and the network VLAN port between the switches is a load-shared port, if the
loopback port is deleted and later re-added, the first packet received in the member port
can be dropped. Subsequent packets are forwarded correctly.
PD4-491938681 A user cannot change the password for a local administrator account when logged in
using a RADIUS administrator account.
PD4-852858182,
PD4-694359201
Process cliMaster dies with signal 6 in some cases.
PD4-944744061,
PD4-935076380
When a switch receives UDP packets with source port 3503, memory depletion occurs
and the switch may reboot.
PD4-539460518,
PD4-539277416
Failsafe account authentication fails when trying to access a switch using SSH by way of
a management port.
PD4-818402813,
PD4-772840867
An Extreme Networks switch ignores the string "priv_lvl" in a TACACS authorization reply
packet.
PD4-876867319,
PD4-862521622
Receiving bootstrap packets with a "Fragment Tag" field set to zero causes memory
depletion in the PIM process when processing subsequent bootstrap packets.
PD4-804570069,
PD4-717931715
After upgrading a PoE capable ExtremeXOS switch from software version ExtremeXOS
11.6 to 12.1, the show configuration poe command is not available.
PD4-806088611,
PD4-605137688
The drop counter for FDB entries is not updated and no log message is generated to
indicate a hash collision or table full error.
PD4-816906321,
PD4-500100211
The "vi" process may crash when performing a cut/copy/paste of text that is larger than
10,492 bytes.
PD4-817311874,
PD4-507170653
Policy files containing 850 entries with flood-groups causes an Extreme Process Manager
(EPM) watchdog reboot.
PD4-825283681,
PD4-699307521
When running the show ports stack-ports rxerrors command, the "RX Over"
count continuously increments, even without user traffic.
PD4-828265339,
PD4-537092174
Enabling diffserv examination on Summit family or BlackDiamond 88000 series switches
causes dot1p replacement of 802.1q tagged packets.
PD4-843338040,
PD4-796910653
The switch stops forwarding traffic after disabling remote mirroring.
Workaround: Delete the ports from the data VLAN and add it back to the VLAN.
PD4-882862442,
PD4-767856469
After running the save command and rebooting a switch with a VLAN translation
configuration, duplicate packets are sent to member VLANs from the translation VLAN.
PD4-899492655,
PD4-505794657
Repeatedly running multiple commands from a telnet session causes memory depletion in
the exsh process.
PD4-929585868,
PD4-507170288
Traffic received on an STP/EAPS blocked port is being sent to the CPU if the source MAC
address of the incoming packet matches the MAC address of the DUT system.
PD4-803700570,
PD4-795451285
After disabling flooding for broadcast traffic, the broadcast traffic originated from the
switch is not flooded out.
PD4-774654053 A 10GE module fails silently followed by a silent MSM failover.
PD4-780725598,
PD4-779916611
When a static entry is added to a configured domain, the entry is also added to another
domain.
PD4-817416641,
PD4-541064246
When configuring rate-limiting on a switch, the max-burst-size value is not reset after
reconfiguring the switch.
PD4-817416749,
PD4-504813986
In a DNS server, if the RADIUS server IP address is specified as CNAME, that is, Alias, a
switch is not able to resolve the IP address correctly.
PD4-932027220,
PD4-698458401
Every 300 seconds, kill entries installed by PIM are not removed from hardware,
therefore, traffic for those entries does not hit the CPU.
Table 44: Platform-Specific and Feature PDs (Continued)
PD Number Description