Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.2 Release Notes
84
Resolved Issues in ExtremeXOS 12.4.1
The following issues were resolved in ExtremeXOS 12.4.1. The numbers shown in column one of the
following table are for internal reference and can be ignored. ExtremeXOS 12.3 includes all fixes up to
and including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5, ExtremeXOS 11.4.4.7,
ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5, ExtremeXOS 12.1.3, ExtremeXOS 12.2.2-
patch1-8, and ExtremeXOS 12.3.3-patch1-4. For information on those fixes, see the release notes for the
specific release.
Table 44: Platform-Specific and Feature PDs
PD Number Description
General
PD4-1168199957,
PD4-1156762929
A triggered IGMP query with the wrong 802.1Q tag is sent on a vMAN enabled port.
PD4-1131636749,
PD4-1099203316
Egress vMAN ACLs are not getting matched, even though the traffic matching the ACL
match condition is egressing the switch port.
PD4-1151118264,
PD4-931823732
A loop occurs after disabling learning on a protected VLAN on an EAPS master.
PD4-1147158779,
PD3-175211031
The ExtremeXOS CLI does not prevent EAPS health check PDUs from looping using the
permit all keywords when installing ACLs.
PD4-448603051 The unconfigure pim vlan command clears (unconfigures) an SSM configuration on
a VLAN but the VLAN continues to operate in the SSM VLAN, even after running the
disable pim and enable pim commands.
PD4-1125058997,
PD4-1111322167
When running the disable subvlan-proxy-arp vlan command on a subVLAN,
clients are not able to resolve the ARP request for the superVLANs interface IP address.
PD4-1110457330,
PD4-938840511
CPU utilization threshold cannot be cleared through SNMP.
Workaround: Run the disable cpu-monitoring command.
PD4-1084310235,
PD4-901582203
A typographical error exists in the following error message and will be corrected in the
next version of ExtremeXOS software:
<Warn:AAA.RADIUS.serverSwitch> MSM-A: Swith to server...
PD4-1084310201,
PD4-901961135
When an SNTP client is configured, the following log message is displayed every 4,096
seconds:
Setting hwclock time to system time, and broadcasting time
Setting hwclock time to system time, and broadcasting time
Setting hwclock time to system time, and broadcasting time
PD4-978931834,
PD4-975759347
When stacking redundancy and telnet access-profiles are configured, the following error is
displayed:
Connection refused
Connection closed by foreign host.
PD4-1028577711,
PD4-995543551
When configuring an ip-mtu as 9,216, the value is reduced to 9,194 after upgrading to
ExtremeXOS 12.1 or later.
PD3-6317414 Secondary DNS and SNTP servers are not contacted if the primary server cannot be
reached.
PD4-1070888667,
PD4-819677511
The show configuration vlan command may also show the QoS profile
configuration for load shared member ports.
PD4-1070888747,
PD4-1028753771
The process "exsshd" crashes with a signal 11 error when closing a session window
without using the proper logout.
PD4-467944506 With IPv6-in-IPv4 tunnels, routes are not learned through RIPng after the port in the
tunnel source VLAN is changed from tagged to untagged or vice versa.