Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.2 Release Notes
81
Resolved Issues in ExtremeXOS 12.4.1-patch1-5
The following issues were resolved in ExtremeXOS 12.4.1-patch1-5. The numbers shown in column one
of the following table are for internal reference and can be ignored. ExtremeXOS 12.4 includes all fixes
up to and including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5,
ExtremeXOS 11.4.4.7, ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5,
ExtremeXOS 12.1.4, ExtremeXOS 12.2.2-patch1-12, and ExtremeXOS 12.3.4. For information on those
fixes, see the release notes for the specific release.
Table 42: Platform-Specific and Feature PDs
PD Number Description
General
PD4-1301482701 ELSM is not responding after rebooting a switch, resulting in the links of neighboring
devices staying down.
Summit Family Switches
PD4-1277806041 An ACL applied to another VLAN is matched even though the ACL is not applied on the
ingress ACL.
MPLS
PD4-1375779654 MPLS next hop is not being programmed in hardware on a BlackDiamond 20800 series
switch that is configured with static routing.
Workaround: Run the configure mpls ldp advertise static none command.
Multicast
PD4-1299398378 IPv4 multicast entries are not cleared after an IP multicast snooping entry times out
when add-ring-ports is enabled.
QoS
PD4-1256063039,
PD4-1142795366
Configuring a QoS profile for all ports using the all keyword fails if load-sharing is
configured on the switch.