Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.4.2 Release Notes
66
PD4-748388236 Egress rate shaping does not work after running the save and reboot commands if an
egress port is not specified. Configured egress rate-shaping does not work on a newly
inserted I/O module if an egress port is not specified.
Workaround: Unconfigure the ACL and re-apply the same ACL.
PD4-715473099 The multicast traffic receive rate for 10,000 multicast groups takes an excessive amount
of processing time.
PD4-756263261 The show fabric command in an ExtremeXOS environment shows the fabric
information is XFM-2.
PD4-728354005 On a BlackDiamond 20808 switch, running the show tech-support command when I/
O modules or fabric slots are in the process of booting, or are otherwise not operational,
may cause sys-health-check output to display fabric link faults, when there are
actually none. This is a transient state. Once the modules are operational, only actual
fabric link faults are displayed in the command output.
PD4-603229266 A slot reboots when load sharing is disabled and MVR is disabled and re-enabled.
PD4-587169451 Running the install firmware command may generate numerous error messages in
the Event Management System (EMS) logs. These messages do not impact system
performance.
<Erro:HAL.Sys.BackupPFCFailed> MM-A: Backup Power Fan Controller
(#2) has failed
<Erro:EPM.Upgrade.Fail> MM-A: Upgrade failed, script: install
bootrom failed
<Erro:HAL.Sys.GetPFCMastershipFailed> MM-A: Failed to get Power
Fan Controller Mastership for slot #17
<Erro:HAL.Sys.OtherPFCFailed> MM-B: Power Fan Controller in slot
17 has failed to communicate with EXOS
<Erro:HAL.Sys.SetBackupPFCToMaster> MM-B: An error happened and
is now setting the backup Power Fan Controller #2 to be the
master Power Fan Controller
<Erro:HAL.Sys.MasterPFCFailed> MM-B: Master Power and Fan
Controller (#1) has failed
<Crit:HAL.Fabric.Critical> MM-A: pioennerBringDownFE200 Bringing
Down FE200 on XBAR 1 as the command EXTRUC_FE_READ_CMD Failed,
Reason: UCPIPE_ERROR
<Erro:HAL.Sys.Error> MM-A: Slot XBAR1: 23918 FE 0 read 0xb50
Summit Family Switches
PD4-749682632 You cannot run the configure port auto on command on XGM2-2bt ports.
PD4-1368980540 Untagged VMAN VPLS service does not encapsulate all VLANS
PD3-127401831 On a Summit X250e platform with 128 VRRP instances that are advertised for 100
milliseconds, the feature "don't preempt" is not working properly.
PD4-1102582531 In a PVLAN, network login MAC-based authentication does not work in ExtremeXOS
12.4.0.19.
PD4-427423116 When a dot1x client is authenticated at multiple VLANs, the output of the show
netlogin port command shows the client is sometimes authenticated at the local
server and other times at a RADIUS server.
Note: This occurs when dot1x and MAC authentication are enabled on the port.
PD4-1101069206 When configuring 2,000 VPWS instances, only 1,023 VPWS instances are created.
Table 39: Platform-Specific and Feature PDs (Continued)
PD Number Description