Specifications
308 ExtremeWare XOS 10.1 Command Reference Guide
Commands for Status Monitoring and Statistics
show powersupplies
show powersupplies {detail}
Description
Displays the current status of the installed power supplies.
Command Syntax
Default
N/A.
Usage Guidelines
Use this command to view detailed information about the health of the power supplies.
This status information may be useful for your technical support representative if you have a network
problem.
The switch collects the following power supply information:
• State—The current state of the power supply. Options are:
— Power On: The power supply is on.
— Power Off: The power supply is off.
— Empty: There is no power supply installed.
• Input Voltage—The input voltage of the power supply.
• PartInfo—Information about the power supply including the:
— Slot number where the power supply is installed.
— Serial number, a collection of numbers and letters, that make up the serial number of the power
supply.
— Part number, a collection of numbers and letters that make up the part number of the power
supply.
• Revision—The revision number of the power supply.
• FailureCode—Specifies the failure code of the power supply.
• Odometer—Specifies the date and how long the power supply has been operating.
• Temperature—Specifies, in celsius, the current temperature of the power supply.
• Output 0 and Output 1—Specifies the output of the power supply.
• Input—Specifies the input of the power supply.
• Voltage 1 and Voltage 2—Specifies the voltage of the power supply.
detail Specifies more detailed power supply information.