Specifications

308 ExtremeWare XOS 10.1 Command Reference Guide
Commands for Status Monitoring and Statistics
show powersupplies
show powersupplies {detail}
Description
Displays the current status of the installed power supplies.
Command Syntax
Default
N/A.
Usage Guidelines
Use this command to view detailed information about the health of the power supplies.
This status information may be useful for your technical support representative if you have a network
problem.
The switch collects the following power supply information:
StateThe current state of the power supply. Options are:
Power On: The power supply is on.
Power Off: The power supply is off.
Empty: There is no power supply installed.
Input VoltageThe input voltage of the power supply.
PartInfoInformation about the power supply including the:
Slot number where the power supply is installed.
Serial number, a collection of numbers and letters, that make up the serial number of the power
supply.
Part number, a collection of numbers and letters that make up the part number of the power
supply.
RevisionThe revision number of the power supply.
FailureCodeSpecifies the failure code of the power supply.
OdometerSpecifies the date and how long the power supply has been operating.
TemperatureSpecifies, in celsius, the current temperature of the power supply.
Output 0 and Output 1Specifies the output of the power supply.
InputSpecifies the input of the power supply.
Voltage 1 and Voltage 2Specifies the voltage of the power supply.
detail Specifies more detailed power supply information.