Specifications
38 ExtremeWare 7.0 Release Notes
Clarifications, Known Behaviors, and Resolved Issues
Synchronize a Newly Installed MSM64i
When you add a slave MSM64i, you are not prompted to synchronize. If not synchronized, the slave
MSM64i uses its image and the master MSM64i configuration. This image/configuration mismatch will
likely cause the switch to operate differently after a failover, thereby defeating the purpose of the dual
MSM64i’s. Be sure the MSM64i’s are synchronized (PD2-101615201).
Disabling CLI Paging from the Slave MSM64i
Enabling or disabling CLI paging from the slave MSM64i has no affect on the master MSM64i paging
configuration (PD2-104377501).
Limited Commands Mode and the reboot Command
In limited commands mode, the reboot command does not reboot the MSM64i; instead the command
causes the MSM64i to fail over (PD2-107053801).
The unconfig switch all Command
If you use the unconfig switch all command and immediately use the config default vlan
delete port all
command, the switch reboots (PD2-105474401). To avoid this situation, after you
unconfigure the switch, wait for the switch to completely reboot before you delete the ports.
Dynamic Memory Scanning and Mapping Module Support
BlackDiamond I/O module memory scanning and mapping support is listed in Table 8.
Extended Diagnostics
The run diagnostics extended command can cause the following messages to appear in the log.
These messages are expected and indicate that the system is currently busy running the user initiated
diagnostics (10800). This does not occur with the
run diagnostics normal command.
<CRIT:SYST> task tdiagTask cpu utilization is 98% PC: 806266e8
<INFO:SYST> task tdiagTask cpu utilization is 98% PC: 806266e8
Table 8: Memory scanning and mapping support in BlackDiamond modules
Module Memory Scanning and Mapping
F32Fi Yes
F48Ti Yes
F96Ti Yes
G12SXi Yes
G8Ti Yes
G8Xi Yes
WDMi Yes
MSM64i Yes