Specifications

84 ExtremeWare Error Message Decoder
Critical Messages
MSM64
i
Packet Problem
<CRIT:SYS> CPU health-check packet missing type 0 on slot 5
<CRIT:SYS> CPU health-check packet problem on card 5
<INFO:SYS> card.C 1937: card5 (type 20) is reset due to autorecovery config reset
counter is 1
Software Version
ExtremeWare 6.x and later
Hardware Version
All
Explanation
These messages indicate that the system is running a system health-check to check the internal
connectivity.
Action
If these messages occur only once or twice, no action is necessary.
If these messages occur continuously, remove and re-insert the module on the slot.
If the removal and re-insertion of the module does not fix the problem, run extended diagnostics on the
switch as this could be a hardware problem.